2019
DOI: 10.1109/jssc.2018.2873630
|View full text |Cite
|
Sign up to set email alerts
|

A Four-Camera VGA-Resolution Capsule Endoscope System With 80-Mb/s Body Channel Communication Transceiver and Sub-Centimeter Range Capsule Localization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
15
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 45 publications
(22 citation statements)
references
References 27 publications
0
15
0
Order By: Relevance
“…In a capacitive coupling method, forward signal path is established through the human body and a return path is formed through the environment. This feature allows the interconnection of devices that are both deployed on the same body surface or close to it, without the need for direct contact with the skin, but can also be used for communication between implanted devices, as was proposed recently [ 146 , 147 , 148 , 149 , 150 ]. The capacitive method allows higher achievable data rates and lower path loss compared to the galvanic IBC method, especially for higher communication distances on the body.…”
Section: State Of the Art: Emerging Technologies For The Wbs Applimentioning
confidence: 99%
See 3 more Smart Citations
“…In a capacitive coupling method, forward signal path is established through the human body and a return path is formed through the environment. This feature allows the interconnection of devices that are both deployed on the same body surface or close to it, without the need for direct contact with the skin, but can also be used for communication between implanted devices, as was proposed recently [ 146 , 147 , 148 , 149 , 150 ]. The capacitive method allows higher achievable data rates and lower path loss compared to the galvanic IBC method, especially for higher communication distances on the body.…”
Section: State Of the Art: Emerging Technologies For The Wbs Applimentioning
confidence: 99%
“…It was shown recently that a stable capacitive return path could be accomplished not only by exposing the capacitive ground electrode directly to the air (e.g., environment), but also in implantable devices in case the ground electrode was isolated from the human tissue [ 146 , 147 , 148 , 149 , 150 , 171 ]. Therefore, the capacitive IBC method emerges as an alternative to communication in the Medical Implant Communication Service (MICS) band of IEEE 802.15.6 NB PHY layer [ 40 ], UWB communication [ 188 , 189 ] or galvanic coupling intrabody communication [ 190 , 191 ], for implementation of communication with implanted devices, such as endoscopic capsules, pacemakers or cochlear implants [ 44 ].…”
Section: State Of the Art: Emerging Technologies For The Wbs Applimentioning
confidence: 99%
See 2 more Smart Citations
“…Subsequently, CR begins to be applied to examination in stomach and large intestine gradually. Representative commercialized capsule products include the PillCam Capsule of Given Imaging Company (Israel), Miro Capsule of Korea, and OMOM Capsule of Chongqing Jinshan Company [2][3].…”
Section: Introductionmentioning
confidence: 99%