1996
DOI: 10.1016/0168-9002(95)00661-3
|View full text |Cite
|
Sign up to set email alerts
|

A focal plane system for the 855 MeV tagged photon spectrometer at MAMI-B

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
59
0

Year Published

1996
1996
2018
2018

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 149 publications
(59 citation statements)
references
References 17 publications
0
59
0
Order By: Relevance
“…The resulting photon beam is collimated onto a target placed in the centre of the Crystal Ball detector (see section 2.3). The recoil bremsstrahlung electrons are energy-tagged in the Glasgow-Mainz Tagged Photon Spectrometer [3][4][5], allowing the energies of the photons to be determined on an event-by-event basis. The scattered electrons are momentum analysed in a large dipole magnet and are detected in a focal plane detector (FPD) consisting of 353 overlapping plastic scintillators.…”
Section: The Glasgow-mainz Photon Taggermentioning
confidence: 99%
“…The resulting photon beam is collimated onto a target placed in the centre of the Crystal Ball detector (see section 2.3). The recoil bremsstrahlung electrons are energy-tagged in the Glasgow-Mainz Tagged Photon Spectrometer [3][4][5], allowing the energies of the photons to be determined on an event-by-event basis. The scattered electrons are momentum analysed in a large dipole magnet and are detected in a focal plane detector (FPD) consisting of 353 overlapping plastic scintillators.…”
Section: The Glasgow-mainz Photon Taggermentioning
confidence: 99%
“…The recoiled electrons are deflected in the magnet of the Glasgow photon tagger [21,22] where their energy E e − is measured in the focal plane detectors with a resolution of ≈ 2 MeV FWHM. In this way, the energy of the photons can be calculated as E γ = E 0 − E e − .…”
Section: Coherent π 0 Photoproduction and Experimental Setupmentioning
confidence: 99%
“…However, even changes of polarizabilities by 100% and more are still compatible with the present error bars. The experiment discussed here has been performed at the continuous-wave electron accelerator MAMI B [25,26] using Glasgow-Edinburgh-Mainz tagger photon facility [1,2]. The quasi-monochromatic photon beam covered the energy range from 537 to 819 MeV with an intensity ∼ 6 × 10 5 /s in the tagger channel for the lowest photon energy and average energy resolution of 2 MeV.…”
Section: Pion Polarizabilitymentioning
confidence: 99%
“…A measurement of the reaction p( γ, π 0 )p [39] was performed at the Mainz Microtron MAMI [40] using the Glasgow/Mainz tagged photon facility [1,2] and the photon spectrometer TAPS [4]. The MAMI accelerator delivered a continuous wave beam of 405 MeV electrons.…”
Section: Pion Polarizabilitymentioning
confidence: 99%
See 1 more Smart Citation