1999
DOI: 10.1016/s0300-5712(98)00048-7
|View full text |Cite
|
Sign up to set email alerts
|

A fluid filtration and clearing technique to assess microleakage associated with three dentine bonding systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
30
1
8

Year Published

2002
2002
2017
2017

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 36 publications
(41 citation statements)
references
References 24 publications
0
30
1
8
Order By: Relevance
“…However, this nanoleakage or nanometer sized spaces within the hybrid layer may result from incomplete resin infiltration into the deminerialized dentin leaving the collagen unenveloped by resin ,or it may result from poor polymerization of the adhesive resin and the existence of low molecular weight oligomers (44) . This nanoleakage pathway may allow fluid penetration along the interface which may result in hydrolytic breakdown of either the adhesive resin or collagen within the hybrid layer, there compromising stability of the resin-dentin bond (45) . Another explanation for drop the shear bond strength values of One-up Bond F plus, without surface treatment after 3 months as result from hydrolytic degradation of the resin and collagen fibers in the submicron spaces of the hybrid layer increase with increase exposure to water (46) .…”
Section: D) Effect Of Storage Time On the Shear Bond Strengthmentioning
confidence: 99%
“…However, this nanoleakage or nanometer sized spaces within the hybrid layer may result from incomplete resin infiltration into the deminerialized dentin leaving the collagen unenveloped by resin ,or it may result from poor polymerization of the adhesive resin and the existence of low molecular weight oligomers (44) . This nanoleakage pathway may allow fluid penetration along the interface which may result in hydrolytic breakdown of either the adhesive resin or collagen within the hybrid layer, there compromising stability of the resin-dentin bond (45) . Another explanation for drop the shear bond strength values of One-up Bond F plus, without surface treatment after 3 months as result from hydrolytic degradation of the resin and collagen fibers in the submicron spaces of the hybrid layer increase with increase exposure to water (46) .…”
Section: D) Effect Of Storage Time On the Shear Bond Strengthmentioning
confidence: 99%
“…A 68% increase in hydraulic conductance was reported after application of a self-etching acid, followed by a return to baseline conductance levels after composite placement. 17 The above explains why the hybrid layer was always 100% infiltrated by pulp fluid when etch & rinse adhesive was applied (Figures 2-5). In contrast, self-etching adhesive was not always infiltrated, because tubule sealing was achieved in some cases ( Figure 6).…”
Section: Discussionmentioning
confidence: 90%
“…16 Phosphoric acid removes the peritubular dentin and fully opens the dentin tubules. Phosphoric etching was reported to produce an increase of 200-300% in hydraulic conductance, 17 and ground dentin showed a fluid flow rate of 0.1 µl/minute compared to 0.9 µl/minute for phosphoric etched dentin. 18 The adhesive must stop the flow of fluid and seal the entire exposed surface.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…, 미생물침투 법 2) , 자가방사법 3) , 주사전자현미경을 이용한 변연적합도 분 석법 4) , 유체이동 측정법 5) , 전기화학적 분석법 6) 등이 이용되 고 있다. 최근에는 3차원적 정량 분석법으로 3차원 재구성 법 7,8) , 미세단층 촬영법 …”
unclassified