A Flexible Experimental Laboratory for Distributed Generation Networks Based on Power Inverters

Abstract: Abstract:In the recently deregulated electricity market, distributed generation based on renewable sources is becoming more and more relevant. In this area, two main distributed scenarios are focusing the attention of recent research: grid-connected mode, where the generation sources are connected to a grid mainly supplied by big power plants, and islanded mode, where the distributed sources, energy storage devices, and loads compose an autonomous entity that in its general form can be named a microgrid. To co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
3
3
1

Relationship

3
4

Authors

Journals

citations
Cited by 20 publications
(14 citation statements)
references
References 63 publications
(108 reference statements)
0
14
0
Order By: Relevance
“…A three-phase distributed generation network composed of four voltage-sourced inverters (VSIs) and one programmable AC power source, which emulates the utility grid, has been implemented in the power network laboratory (PNL). Details on the design and implementation of the experimental test bench can be found in the literature [34]. Each generation node (DPGS) is composed of a three-phase inverter with an output LC filter connected to the network through a wye-delta transformer.…”
Section: Multiple Grid-connected Inverters Under Voltage Sagsmentioning
confidence: 99%
See 2 more Smart Citations
“…A three-phase distributed generation network composed of four voltage-sourced inverters (VSIs) and one programmable AC power source, which emulates the utility grid, has been implemented in the power network laboratory (PNL). Details on the design and implementation of the experimental test bench can be found in the literature [34]. Each generation node (DPGS) is composed of a three-phase inverter with an output LC filter connected to the network through a wye-delta transformer.…”
Section: Multiple Grid-connected Inverters Under Voltage Sagsmentioning
confidence: 99%
“…However, most of these strategies were presented for a single inverter connected to the grid. Nevertheless, some works address the issue of the operation of multiple inverter-based renewable distributed generators [28][29][30][31][32][33][34]. In the literature [28], the coordinated operation between a wind farm and a static synchronous compensator (STATCOM) in a power network is studied.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…It is based on reducing the amplitude and frequency of the reference voltages according to the reactive Q and active P powers delivered by the inverter [17,26,27] (26) The droop control method makes possible to operate several inverters simultaneously as voltage sources [5,8]. It is based on reducing the amplitude V re f and frequency ω re f of the reference voltages according to the reactive Q and active P powers delivered by the inverter [17,26,27] …”
Section: Ivs Control Schemementioning
confidence: 99%
“…The design guidelines provided in [17,25,30] are used to properly tune the parameters of GCCS, IVS and GCVS control schemes, respectively. In particular, the gains of the PI controllers only impact on the dynamic characteristics of the microgrid, providing a fast transient response with small overshoot when the design guidelines are observed.…”
Section: Simulation Setupmentioning
confidence: 99%