“…In Figure b, a biconvex lens was used for the better collection of S 2 * emission light by H5784, which was placed 2 mm away from the lens. Our previous work has proved that a broad-band pass filter together with a QB21 glass could increase the SNR of FPD compared with a narrow-band pass filter when a photodiode assembly (PDA) was used as a photodetector . For PMT, however, the situation is different.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…In Figure b, a biconvex lens was used for the better collection of S 2 * emission light by H5784, which was placed 2 mm away from the lens. Our previous work has proved that a broad-band pass filter together with a QB21 glass could increase the SNR of FPD compared with a narrow-band pass filter when a photodiode assembly (PDA) was used as a photodetector . For PMT, however, the situation is different.…”
Section: Resultsmentioning
confidence: 99%
“…Our previous work has proved that a broad-band pass filter together with a QB21 glass could increase the SNR of FPD compared with a narrow-band pass filter when a photodiode assembly (PDA) was used as a photodetector. 36 For PMT, however, the situation is different. It was found that only a slight improvement in the SNR was observed using a broad-band pass filter and an additional focus lens because the signal and noise level increased simultaneously, as shown in Table S2.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In this case, the advantage of the large photosensitive surface of S2386-44K is more obvious. 19 Evaluation of the Multichannel Fluorescence Detector by FIA. The performance of the developed multichannel fluorescence detector was evaluated in terms of LOD, linear range of response, and repeatability as shown in Figure 3.…”
Section: ■ Introductionmentioning
confidence: 99%
“…Numerous reports are available for the micro-level determination of sulfur-containing drugs and molecules in biological samples and pharmaceutical preparations [20][21][22][23]. The determination methods includes potentiometry [24], NMR-spectrometry [25], colorimetry [20], chromatography [26][27][28], flow injection analysis [29], fluorimetry [30], voltammetry [31] and spectrophotometry [32,33]. The high initial investment, timeconsuming processes, high costs of sample analysis, and heavy instrumentation are major concerns of many reported methods.…”
Section: Introductionmentioning