2021
DOI: 10.1002/2050-7038.12816
|View full text |Cite
|
Sign up to set email alerts
|

A first swing stability improvement approach in microgrids with synchronous distributed generators

Abstract: Summary One of the effective approaches to maintain power generation consumption balance during contingencies and therefore transient stability of the system is instantaneous rise of generation power and changing the generators excitation control system. This article proposes an auxiliary droop controller, which can replace generator main controller in order to maintain the transient stability of the system at the time of fault occurrence. Because of its linear structure, the proposed droop controller has a hi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 45 publications
0
4
0
Order By: Relevance
“…Te diferential load fow approach has shown that this method is efective in solving transient stability simulation [7,25]. Te researchers in [7] have further shown that the nonlinear AC power fow can be transformed into a set of equivalent linear equations that does not need any iteration.…”
Section: Overview Of Atc Available Transmission Capacitymentioning
confidence: 99%
“…Te diferential load fow approach has shown that this method is efective in solving transient stability simulation [7,25]. Te researchers in [7] have further shown that the nonlinear AC power fow can be transformed into a set of equivalent linear equations that does not need any iteration.…”
Section: Overview Of Atc Available Transmission Capacitymentioning
confidence: 99%
“…Considering the nonlinearity of the model in (25) and the advantage of the direct optimization, the interior point method is introduced, which requires the frst-order and second-order gradient information of the objective function. By accumulating the TS of the objective function J to a, the frst-order gradient is obtained by (26), where NUM ste is the number of the simulation steps and S δ j (t m ),a is the TS of the power angle of the #j SG to a at the m th step.…”
Section: Multiparameter Coordinated Optimization Considering the Opti...mentioning
confidence: 99%
“…Considering that the frst-order gradient in (26) is not suitable for diference periods of multiple parameters, this paper proposes the extended frst-order gradient with the improved TS in ( 28) and (29).…”
Section: Multiparameter Coordinated Optimization Considering the Opti...mentioning
confidence: 99%
See 1 more Smart Citation
“…There may be a chance of power swing following the fault in islanded microgrid with multiple synchronous-based DGs [40].…”
Section: Performance During Power Swingmentioning