2023
DOI: 10.1186/s13244-022-01350-0
|View full text |Cite
|
Sign up to set email alerts
|

A feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors

Abstract: Objectives This study aimed to evaluate the feasibility of reduced full-of-view synthetic high-b value diffusion-weighted images (rFOV-syDWIs) in the clinical application of cervical cancer based on image quality and diagnostic efficacy. Methods We retrospectively evaluated the data of 35 patients with cervical cancer and 35 healthy volunteers from May to November 2021. All patients and volunteers underwent rFOV-DWI scans, including a 13b-protocol:… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2
1

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 50 publications
2
3
0
Order By: Relevance
“…Therefore, a multiple-b-value protocol played a key role in synthesizing high-b-value DWIs with better background suppression and lesion conspicuity (i.e., higher SNR/CNR). In consistent with our previous study of synthetic 5b-protocol FOCUS DWI on a 1.5T MR scanner [29], 5b-protocol syFOCUS-MUSE 5b,1500 possessed higher SNR than sFOCUS-MUSE b=1500 but lower than 13b-protocol syFOCUS-MUSE 13b,1500 and 5b-protocol syFOCUS 5b,1500 . ) as well as offer diagnosis and prognosis of tumor histological heterogeneity information even including in low-and high-grade positive-and negative CC [43].…”
Section: Discussionsupporting
confidence: 91%
See 3 more Smart Citations
“…Therefore, a multiple-b-value protocol played a key role in synthesizing high-b-value DWIs with better background suppression and lesion conspicuity (i.e., higher SNR/CNR). In consistent with our previous study of synthetic 5b-protocol FOCUS DWI on a 1.5T MR scanner [29], 5b-protocol syFOCUS-MUSE 5b,1500 possessed higher SNR than sFOCUS-MUSE b=1500 but lower than 13b-protocol syFOCUS-MUSE 13b,1500 and 5b-protocol syFOCUS 5b,1500 . ) as well as offer diagnosis and prognosis of tumor histological heterogeneity information even including in low-and high-grade positive-and negative CC [43].…”
Section: Discussionsupporting
confidence: 91%
“…Similarly, there was the excellent agreement of diagnostic performance for syADC 10b,1500 and sADC 10b,1500 in assessment of liver, spleen, and paravertebral muscles in pediatric patients [30]. In other words, high-b-value-computed ADC could be derived from low-b-value DWIs with relatively small errors regardless of magnetic eld strength [29,44]. Moreover, syFOCUS-MUSE 13b/5b,1500 with both features of MUSE DWI and FOCUS DWI mitigated imaging interference factors and had more reliable ADC values for tumor staging.…”
Section: Discussionmentioning
confidence: 98%
See 2 more Smart Citations
“…Histogram-derived ADC values-mean and median of both actually scanned and synthetic ADC values reached perfect diagnosis e cacy with AUC of almost close and equal to 1.000 in our study, implying mean and median of ADC values possess good diagnosis e cacy in detection of prostate cancer and its invasiveness [28,29] .There was no difference of 5b-protocol and 13b-protocol mean and median of syADC b=1000, 1500 in tumor tissues. In accordance to a study of synthetic high-b-value DWIs in diagnosis of cervical cancer [30] , the diagnosis e cacy of both 5b-protocol and 13b-protocol syADC mean, b=1000, 1500 was rather competitive. This result might attribute to several reasons.…”
Section: Quantitative Assessmentsupporting
confidence: 74%