2017
DOI: 10.1089/lap.2017.0093
|View full text |Cite
|
Sign up to set email alerts
|

A Feasibility Study and Technical Tips for the Use of an Articulating Bipolar Vessel Sealer in da Vinci Robot-Assisted Gastrectomy

Abstract: Use of the VS in robotic gastrectomy was feasible and provided good configuration in the direction of dissection. The learning process for use of the VS in the initial series was relatively rapid, resulting in comparable results between the VS and US groups. Reduced inflammation and albumin loss were identified as possible benefits of the VS.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(2 citation statements)
references
References 28 publications
0
2
0
Order By: Relevance
“…A retrospective analysis of 72 robotic procedures by Ortenzi et al [ 16 ] has concluded that it is safe with decreased overall operative time. In a study by Kong et al [ 17 ] of 17 patients of robotic gastrectomy for gastric cancer, it was concluded that the use of the VS in robotic gastrectomy was feasible, providing exemplary configuration in the direction of dissection, rapid learning curve, and comparable results between VS and conventional ultrasonic shear groups. At the same time, it can reduce inflammation with less albumin loss as possible benefits of the VS.…”
Section: Discussionmentioning
confidence: 99%
“…A retrospective analysis of 72 robotic procedures by Ortenzi et al [ 16 ] has concluded that it is safe with decreased overall operative time. In a study by Kong et al [ 17 ] of 17 patients of robotic gastrectomy for gastric cancer, it was concluded that the use of the VS in robotic gastrectomy was feasible, providing exemplary configuration in the direction of dissection, rapid learning curve, and comparable results between VS and conventional ultrasonic shear groups. At the same time, it can reduce inflammation with less albumin loss as possible benefits of the VS.…”
Section: Discussionmentioning
confidence: 99%
“…However, Kang et al 24 and Jin et al 25 both reported a shorter learning curve period for RG compared with LG, and both surgeons in this study had performed more than 40 RGs before the study period to minimize any learning curve effect. Another limitation of this study is that we did not assess the usefulness of bipolar vessel-sealing devices, 26 because the tips of such devices are too large and blunt to use for meticulous procedures such as lymphadenectomy. If future devices become smaller and sharper, we would need to assess their usefulness in the future.…”
Section: Discussionmentioning
confidence: 99%