2017
DOI: 10.1109/tia.2017.2665630
|View full text |Cite
|
Sign up to set email alerts
|

A Fault-Tolerant T-Type Multilevel Inverter Topology With Increased Overload Capability and Soft-Switching Characteristics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
24
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 56 publications
(25 citation statements)
references
References 17 publications
0
24
0
Order By: Relevance
“…The three duty ratios for the three-phase inverter with the switching frequency optimal (SFO)-PWM-PD scheme [13] are given in (5) and (6)…”
Section: Current Sharing In Sfo-pwm-pd Schemementioning
confidence: 99%
See 2 more Smart Citations
“…The three duty ratios for the three-phase inverter with the switching frequency optimal (SFO)-PWM-PD scheme [13] are given in (5) and (6)…”
Section: Current Sharing In Sfo-pwm-pd Schemementioning
confidence: 99%
“…Furthermore, there are many redundant devices kept constant on during normal operation, which obviously causes additional device losses and decreases the converter efficiency. Another fault-tolerant three-phase four-leg T-Type converter topology was recently reported in [5]. This topology can tolerate any open-circuit and certain short-circuit power semiconductor faults.…”
Section: Section I Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…As far as the price of SiC devices is concerned, if all six switching devices in the ANPC topology are replaced with SiC devices, the high cost will limit the widespread application of such products. Considering this problem, many studies have proposed hybrid applications of SiC and silicon (Si) devices, that is, only some of the devices in a system or topology are replaced with SiC devices [5][6][7][8][9][10][11][12][13][14][15][16][17][18][19]. In [5], a Si CSI (current source inverter)/SiC VSI (voltage source inverter) series inverter system was proposed.…”
Section: Introductionmentioning
confidence: 99%
“…Compared with traditional Si devices, the low switching loss characteristics of SiC devices can greatly reduce the total circuit losses. In [6], a fault-tolerant T-T structure multilevel three-phase inverter is proposed, in which the devices of redundant bridge arms were replaced by SiC MOSFETs. Its working principle is to realize ZVS (zero voltage switching) and ZCS (zero current switching) of the main circuits through the advance switch of the redundant bridge arm.…”
Section: Introductionmentioning
confidence: 99%