PACS2001. Proceedings of the 2001 Particle Accelerator Conference (Cat. No.01CH37268)
DOI: 10.1109/pac.2001.988231
|View full text |Cite
|
Sign up to set email alerts
|

A fast injection kicker magnet for the Tevatron

Abstract: A new proton injection kicker system is required for the Tevatron in the Run II era. The new system was designed to supply 1.25 kG-m into a magnetic aperture of 48 mm vertical x 71 mm horizontal x 5 m long with a 396 ns bunch spacing. The system is configured to be upgraded to a bunch spacing of 132 ns with additional pulsed power supplies. The design of the magnet incorporated some novel features in order to meet these requirements. These include adjustable bus spacing to set the inductance, balanced positive… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 3 publications
0
8
0
Order By: Relevance
“…Significant money and effort were spent to build prototypes starting three years before operation was required. Since the magnet is covered in a companion paper [4], the remainder of this paper will focus on the power supply.…”
Section: System Designmentioning
confidence: 99%
See 1 more Smart Citation
“…Significant money and effort were spent to build prototypes starting three years before operation was required. Since the magnet is covered in a companion paper [4], the remainder of this paper will focus on the power supply.…”
Section: System Designmentioning
confidence: 99%
“…We relied on custom, built in capacitive pickups in the magnet [4]. The response of the installed systems, shown in Figure 3, was calculated using a spreadsheet and the measured magnet input and output voltages.…”
Section: Performancementioning
confidence: 99%
“…This effect has been further described and modelled at TRIUMF in 1989 [11]. More recently, counter-coupling has been successfully applied at FNAL for the Tevatron injection kicker magnets [12] (Fig. 2).…”
Section: Optimising the Rise Timementioning
confidence: 99%
“…To gain in filling time by a factor of two compared to a classical C-topology FNAL and KEK used a windowframe topology [12,13] (Fig. 2).…”
Section: Optimising the Rise Timementioning
confidence: 99%
See 1 more Smart Citation