2023
DOI: 10.1109/tii.2022.3217474
|View full text |Cite
|
Sign up to set email alerts
|

A Fast Impedance Measurement Method for Lithium-Ion Battery Using Power Spectrum Property

Abstract: Electrochemical Impedance Spectroscopy (EIS) can provide fruitful information for Lithium-ion (Li-ion) battery modelling and diagnosis, yet EIS measurement is time-consuming with low-frequency signal injection. By stacking a group of broadband signals, Pseudo Random Sequence (PRS) makes it possible to obtain the battery EIS in a few seconds at the expense of measurement accuracy and Signal-to-Noise Ratio (SNR). Thus, this paper focuses on developing a highly effective signal processing procedure to extract use… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(2 citation statements)
references
References 28 publications
0
2
0
Order By: Relevance
“…In [29,30], the moving average filter (MAF) was used to smooth the impedance curve and reduce the measurement error, which was suitable for suppressing the noise in the middle and low-frequency ranges. The authors of [31,32] proposed an impedance denoising and filtering method using the power spectral density and frequency characteristics of PRBS to accurately extract the impedance in the full frequency interval [0.21 Hz, 3.5 kHz]. It was noticed that the impedance extraction method based on MAF had a large calculation error because it failed to effectively eliminate the measurement noise.…”
Section: Introductionmentioning
confidence: 99%
“…In [29,30], the moving average filter (MAF) was used to smooth the impedance curve and reduce the measurement error, which was suitable for suppressing the noise in the middle and low-frequency ranges. The authors of [31,32] proposed an impedance denoising and filtering method using the power spectral density and frequency characteristics of PRBS to accurately extract the impedance in the full frequency interval [0.21 Hz, 3.5 kHz]. It was noticed that the impedance extraction method based on MAF had a large calculation error because it failed to effectively eliminate the measurement noise.…”
Section: Introductionmentioning
confidence: 99%
“…Newly developed faster methods include the excitation of lithium-ion batteries using a multi-sine signal, whose response is then processed using fast-Fourier transform (FFT) or excitation of the battery using a Pseudo Random Sequence (PRS) [5].…”
Section: Introductionmentioning
confidence: 99%