2020
DOI: 10.1007/s00542-020-04946-y
|View full text |Cite
|
Sign up to set email alerts
|

A fast digital chip implementing a real-time noise-resistant algorithm for estimating blood pressure using a non-invasive, cuffless PPG sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 23 publications
0
5
0
Order By: Relevance
“…Several studies agree on considering pulse rate variability assessed from PPG as a surrogate of heart rate variability [ 15 , 81 , 82 ], and recent studies have also investigated the use of PPG time series shorter than 300 samples as an alternative for the standard ST analysis [ 31 , 83 ]. Moreover, analyzing PPG signals also allows information to be extracted on blood pressure [ 84 ], and this would to achieve insight into both heart rate and blood pressure variability which, as seen from our results, often yield complementary results.…”
Section: Discussionmentioning
confidence: 99%
“…Several studies agree on considering pulse rate variability assessed from PPG as a surrogate of heart rate variability [ 15 , 81 , 82 ], and recent studies have also investigated the use of PPG time series shorter than 300 samples as an alternative for the standard ST analysis [ 31 , 83 ]. Moreover, analyzing PPG signals also allows information to be extracted on blood pressure [ 84 ], and this would to achieve insight into both heart rate and blood pressure variability which, as seen from our results, often yield complementary results.…”
Section: Discussionmentioning
confidence: 99%
“…Several studies agree on considering pulse rate variability assessed from PPG as a surrogate of heart rate variability [23,79,80] and recent studies have also investigated the use of PPG time series shorter than 300-samples as an alternative for the standard ST analysis [33,78]. Moreover, analyzing PPG signals allow to extract information also on blood pressure [81,82], and this would permit to achieve an insight into both heart rate and blood pressure variability which, as seen from our results, often yield complementary results.…”
Section: Discussionmentioning
confidence: 99%
“…Based on the experimental results obtained by [ 38 ], the elastic modulus of an artery can be represented as [ 13 ]: where is the elastic modulus at zero pressure and is the coefficient depending on the particular vessel. The values of these two parameters are taken as 1428.7 and 0.031, respectively, which are the average values obtained in the study carried out by [ 38 ] for the brachial artery and have been used in a number of studies [ 13 , 39 , 40 ]. is the mean blood pressure and can be derived by: while and are parameters that need to be calibrated for an individual by experiment [ 13 ].…”
Section: Methodsmentioning
confidence: 99%
“…The peak of the reflected wave can be located using the second derivative of the PPG signal (diastolic peak) [ 41 ]. The separation between the systolic and diastolic peaks on the time axis marks the reflective PTT [ 40 ]. Figure 5 shows the PPG waveform, its first and second derivatives, and the R-PTT.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation