A fast alignment method for grating-based X-ray phase-contrast imaging systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(13 citation statements)
references
References 41 publications
(52 reference statements)
0
11
0
Order By: Relevance
“…Furthermore, the distances between the two gratings match the Talbot distance of the G1 grating, calculated for the expected 11 keV. The alignment process of the portable interferometer with respect to the backligher source was performed using the fast-alignment method described in [28]. 20 mm 75 mm 726 mm 868 mm X-rays laser object 10 µm G1 phase grating 6 µm G2 absorption grating imaging plate detector tungsten wire Figure 3.…”
Section: Methodsmentioning
confidence: 97%
See 2 more Smart Citations
“…Furthermore, the distances between the two gratings match the Talbot distance of the G1 grating, calculated for the expected 11 keV. The alignment process of the portable interferometer with respect to the backligher source was performed using the fast-alignment method described in [28]. 20 mm 75 mm 726 mm 868 mm X-rays laser object 10 µm G1 phase grating 6 µm G2 absorption grating imaging plate detector tungsten wire Figure 3.…”
Section: Methodsmentioning
confidence: 97%
“…Furthermore, the distances between the two gratings match the Talbot distance of the G1 grating, calculated for the expected 11 keV. The alignment process of the portable interferometer with respect to the backligher source was performed using the fast-alignment method described in [ 28 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The horizontal size is about 10 μm to 20 μm depending on the laser intensity [34]. Thus, the thin backlighter wire provides x-rays with sufficient spatial coherence, so that a good moiré visibility can be achieved without using a source grating [14,27].…”
Section: Instrumentationmentioning
confidence: 99%
“…Furthermore, using only two instead of three gratings increases the photon-flux at the detector and improves the flexibility of the setup. Phase and attenuation images were obtained with a robust two-grating phase-contrast setup that was aligned using a fast alignment method [27]. In-line signatures were identified in the transmission images and evaluated separately to confirm the findings from the phase-reconstructions.…”
Section: Introductionmentioning
confidence: 99%