2017
DOI: 10.24027/2306-7039.1a.2017.100007
|View full text |Cite
|
Sign up to set email alerts
|

A Facility for Spectral Emissivity Measurement under Vacuum for Industrial and Remote Sensing Applications

Abstract: A variety of techniques for the measurement of emissivity is available today but in many cases these techniques do not adequately meet the wide range of requirements posed by modern science and industry. Furthermore, they do not provide sufficiently accurate results and lack reliable and traceable uncertainties. Therefore, a measurement setup and a validated method for highly accurate directional spectral emissivity, total directional emissivity and total hemispherical emissivity measurements under vacuum in t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2017
2017
2017
2017

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…The emissivity measurements of the black coatings were taken at two setups at PTBunder vacuum at the RBCF and in air at the EMAF-by applying the measurement schemes and data, and uncertainty evaluation described shortly above and described in detail in [1][2][3]6,7]. Two sets of detectors and beamsplitters were used with the IR-FTS according to the wavelength and temperature range of the measurements.…”
Section: Experimental Results On Different Black Coatingsmentioning
confidence: 99%
See 2 more Smart Citations
“…The emissivity measurements of the black coatings were taken at two setups at PTBunder vacuum at the RBCF and in air at the EMAF-by applying the measurement schemes and data, and uncertainty evaluation described shortly above and described in detail in [1][2][3]6,7]. Two sets of detectors and beamsplitters were used with the IR-FTS according to the wavelength and temperature range of the measurements.…”
Section: Experimental Results On Different Black Coatingsmentioning
confidence: 99%
“…Highly accurate measurements of directional spectral, directional total and hemispherical total emissivities for four widely used black coatings-Nextel 811-21, Herberts 1534, Aeroglaze Z306 and Acktar Fractal Black-were taken by PTB in the wavelengths range from 4 µm to 100 µm at different temperatures in the range from 25 • C to 150 • C. The achieved absolute standard uncertainty (k = 1) is calculated according to [5][6][7]. It is 0.005 or better for measurements at high temperatures (T = 120 • C and T = 150 • C) and it is better than 0.022 (for some measurements better than 0.011) for measurements at 25 • C. It should be noted that the achieved uncertainty significantly depends on the experimental conditions and the investigated coating.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation