2016 International Conference on Probabilistic Methods Applied to Power Systems (PMAPS) 2016
DOI: 10.1109/pmaps.2016.7764208
|View full text |Cite
|
Sign up to set email alerts
|

A dynamic programming-based heuristic approach for optimal transmission switching problem with N-1 reliability criterion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 15 publications
0
4
0
1
Order By: Relevance
“…An AC-OPF based OTS reliability assessment with N-1 standards is studied on the Tennessee Valley Authority (TVA) network in [170] to show that OTS can help relive voltage and thermal violations in post-contingency situations. A dynamic programming approach is used to model OTS in an AC-OPF based formulation considering the N-1 security analysis to reduce the computational time of solving the problem [171]. On the contrary, the authors in [102] argue that system reliability using AC-OPF based formulation remains unchanged while DC based model can help improve system reliability.…”
Section: Figure 14 Flowchart For Reliability Evaluation Of Otsmentioning
confidence: 99%
“…An AC-OPF based OTS reliability assessment with N-1 standards is studied on the Tennessee Valley Authority (TVA) network in [170] to show that OTS can help relive voltage and thermal violations in post-contingency situations. A dynamic programming approach is used to model OTS in an AC-OPF based formulation considering the N-1 security analysis to reduce the computational time of solving the problem [171]. On the contrary, the authors in [102] argue that system reliability using AC-OPF based formulation remains unchanged while DC based model can help improve system reliability.…”
Section: Figure 14 Flowchart For Reliability Evaluation Of Otsmentioning
confidence: 99%
“…Fundamentally, it is the lack of harmony between the reactance, capacity, and location of these bottleneck lines that causes the congestion elsewhere. Indeed, the various existing optimal transmission switching methodologies [13]- [16] could be viewed in this light, as removing a line increases its reactance to infinity.…”
Section: A Shadow Capacity Analysismentioning
confidence: 99%
“…El análisis principalmente se lo realiza bajo los parámetros de voltajes del sistema [11][16] [28]. El tipo de problema que se plantea es MILP (programación lineal entera mixta), con variables binarias; las variables binarias representaran el estado de operación de las líneas, también es necesario el uso de un Flujo de Potencia Optimo para verificar el comportamiento del SEP antes y después de la perturbación [29], [30], [31]; por medio de un flujo óptimo de carga se obtendrá los niveles de potencia que se genera para abastecer la etapa de demanda, por ultimo con el OTS se obtiene la topología de la etapa de transmisión después de la perturbación [32] [33]. La finalidad es mantener la estabilidad del sistema, reduciendo el uso de los recursos; otro factor importante del método OTS es reducir el costo operativo cuando el sistema presenta fallas inesperadas, manteniendo niveles de tensión y frecuencia de manera óptima y satisfaciendo el balance de potencias (la potencia generada será igual a la demanda necesaria más las pérdidas producidas en el sistema) [34] [35].…”
Section: Aplicaciones De La Conmutación De Líneas De Transmisiónunclassified