XI Brazilian Power Electronics Conference 2011
DOI: 10.1109/cobep.2011.6085271
|View full text |Cite
|
Sign up to set email alerts
|

A dual unified power quality conditioner using a simplified control technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0
4

Year Published

2013
2013
2018
2018

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(12 citation statements)
references
References 10 publications
0
8
0
4
Order By: Relevance
“…The series and shunt APFs are operated with a classical PI (Proportional Integration) controllers. The control of series inverter is sinusoidal Pulse Width Modulation (PWM) and the shunt inverter is hysteresis current control [2,7,22,23,24]. The conventional configuration of UPQC with the its dynamic control equations characterizing the feedback signals are well documented [1 -4, 22, 23, 24, 25], and hence, are not presented in this paper.…”
Section: Structure and Principal Operationmentioning
confidence: 99%
“…The series and shunt APFs are operated with a classical PI (Proportional Integration) controllers. The control of series inverter is sinusoidal Pulse Width Modulation (PWM) and the shunt inverter is hysteresis current control [2,7,22,23,24]. The conventional configuration of UPQC with the its dynamic control equations characterizing the feedback signals are well documented [1 -4, 22, 23, 24, 25], and hence, are not presented in this paper.…”
Section: Structure and Principal Operationmentioning
confidence: 99%
“…No entanto, também existe a possibilidade de modelar e controlar os conversores de um UPQC como fontes de tensão e corrente senoidais [52][53][54][55][56], da mesma maneira que é feito com as UPSs conforme apresentado na seção anterior.…”
Section: Topologias De Fontesunclassified
“…A principal vantagem desta topologia se caracteriza pela menor quantidade de dispositivos semicondutores de potência, pelo fato do condutor de neutro ser conectado diretamente ao ponto central do barramento CC. No entanto, o inerente desequilíbrio de tensão no barramento CC leva a necessidade de utilização de um ou mais malhas de controle para contornar tal problema [54,55]. Além disso, desconsiderando as perdas nos conversores, a tensão total do barramento CC deve ser no mínimo o dobro do pico da tensão CA de fase na saída, tendo como consequência a necessidade de utilizar uma quantidade maior de baterias para operação como UPS, elevando os custos de implementação.…”
Section: Topologias De Upqc/ups Trifásica a Quatro Fios Com Condicionunclassified
See 2 more Smart Citations