2018
DOI: 10.1039/c7ra12252g
|View full text |Cite
|
Sign up to set email alerts
|

A dual-emission nano-rod MOF equipped with carbon dots for visual detection of doxycycline and sensitive sensing of MnO4

Abstract: A dual-emission hybrid material could detect doxycycline and MnO4− sensitively. Test paper was regarded initially as a tool for doxycycline visual detection. A lower LOD of MnO4− showed that carbon dots can accelerate quenching speed of MOF(Eu).

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
51
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 76 publications
(51 citation statements)
references
References 45 publications
0
51
0
Order By: Relevance
“…MnO 4 − is another strong oxidant that extensively used both in industry and laboratories . Besides, it can also be applied to treating polluted water and fish diseases as disinfection and antiseptic in low concentration . Indeed, MnO 4 − is also very harmful to human health and can lead to gastrointestinal disorders, skin, respiratory infection, liver and kidney damage and even deformity .…”
Section: Introductionmentioning
confidence: 99%
“…MnO 4 − is another strong oxidant that extensively used both in industry and laboratories . Besides, it can also be applied to treating polluted water and fish diseases as disinfection and antiseptic in low concentration . Indeed, MnO 4 − is also very harmful to human health and can lead to gastrointestinal disorders, skin, respiratory infection, liver and kidney damage and even deformity .…”
Section: Introductionmentioning
confidence: 99%
“…That is to say, the uorescence of MOFs can serve as the second signal of ratiometric mode when uorescent probes and MOFs are integrated together, thus improving the accuracy of uorescent probes. [47][48][49][50][51][52][53][54][55][56][57] There have been four strategies proposed to endow uorescent probes with ratiometric mode via MOFs. The rst strategy is integrating a uorescent probe into a uorescent MOF that serves as the reference uorophore.…”
Section: Accuracy Regulationmentioning
confidence: 99%
“…This system exhibited LODs of 0.015 and 0.014 µM for 6-TG and 6-MP, respectively. The detection of other types of drugs, such as oxytetracycline [ 259 ], chlortetracycline and doxycycline [ 260 ], glucosamine [ 71 ], kanamycin [ 261 ], quercetin [ 262 ], lidocaine hydrochloride [ 263 ], has been reported using CD-based fluorescence nanoprobes using various quenching mechanism including PET, IFE, and FRET.
Fig.
…”
Section: Sensing Applicationsmentioning
confidence: 99%