A double-pass interferometer for measurement of dimensional changes

Abstract: A double-pass interferometer was developed for measuring dimensional changes of materials in a nanoscale absolute interferometric dilatometer. This interferometer realized the double-ended measurement of a sample using a single-detection double-pass interference system. The nearly balanced design, in which the measurement beam and the reference beam have equal optical path lengths except for the path difference caused by the sample itself, makes this interferometer have high stability, which is verified by the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0

Year Published

2009
2009
2021
2021

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 9 publications
(9 citation statements)
references
References 14 publications
0
9
0
Order By: Relevance
“…The linear operator h i is a 16×16 matrix, the elements of which are detailed in Eqs. (10) and (11) in Appendix A. The calibrated PSG matrix w is then the non-zero solution to Eq.…”
Section: Step 1: Determining the Properties Of Calibration Samplesmentioning
confidence: 99%
See 1 more Smart Citation
“…The linear operator h i is a 16×16 matrix, the elements of which are detailed in Eqs. (10) and (11) in Appendix A. The calibrated PSG matrix w is then the non-zero solution to Eq.…”
Section: Step 1: Determining the Properties Of Calibration Samplesmentioning
confidence: 99%
“…Inherited from standard interferometry [9], the double-pass configuration detecting the phase shift between its two arms has been developed for sensing applications such as dilatometric measurement [10] and pH monitoring [11]. In polarimetry, a doublepass layout enables angle-resolved measurements, whereby the polarization response of a sample for a range of polar angles and all azimuths can be measured in a synchronous approach.…”
Section: Introductionmentioning
confidence: 99%
“…The initial interferometer analyzed is based on a double-pass dilatometer design by Ren et al [12]. This interferometer has been modified, which is shown in Fig.…”
Section: Double-pass Interferometermentioning
confidence: 99%
“…Inherited from standard interferometry [9], the doublepass configuration detecting the phase shift between its two arms has been developed for sensing applications such as dilatometric measurement [10] and pH monitoring [11]. In polarimetry, a double-pass layout enables angle-resolved measurements, whereby the polarization response of a sample for a range of polar angles and all azimuths can be measured in a synchronous approach.…”
Section: Introductionmentioning
confidence: 99%