2023
DOI: 10.1007/s11224-023-02182-4
|View full text |Cite
|
Sign up to set email alerts
|

A dispersion-corrected DFT calculation on encapsulation of favipiravir drug used as antiviral against COVID-19 into carbon-, boron-, and aluminum-nitride nanotubes for optimal drug delivery systems combined with molecular docking simulations

Abstract: Favipiravir (FAV) (6-fluoro-3-oxo-3,4-dihydropyrazine-2-carboxamide) is one of the most effective antiviral drugs which is cited for action against RNA-viral infections of COVID-19. In this study, density functional theory (DFT) calculations were used to investigate three nanotubes (NTs) with FAV drug as delivery systems. The encapsulated systems (ESs) consist of FAV drug inside carbon–carbon, aluminum nitride, and boron nitride. At B3LYP-D/6-31G(d,p) and CPCM/B3LYP-D/6-31G(d,p), the optimization of NTs, FAV, … Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
0
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(7 citation statements)
references
References 82 publications
0
0
0
Order By: Relevance
“…The mean differences between the G S values calculated analytically with the help of Equation ( 20) and those acquired from the FEA results by Equation ( 15) are 0.13%, 0.17%, 0.59%, 0.19%, and 0.26% (1.46%, 1.74%, 2.83%, 2.45%, and 1.97% for NTs with D n ≲ 1.5 nm), for the SWBNNTs, SWAlNNTs, SWGaNNTs, SWInNNTs, and SWTlNNTs, respectively. It can be assumed that Equation (20) leads to an accurate evaluation of the surface shear modulus of the 13th group atom-nitride nanotubes across the entire range of the NT diameters considered in the current study, although the error obtained for NTs with D n up to 1.5 nm is slightly higher. The G S values calculated by Equation (20) are shown in Figure 9b as a function of the bond length, a A13−N .…”
Section: Surface Shear Modulus and Poisson's Ratiomentioning
confidence: 90%
See 4 more Smart Citations
“…The mean differences between the G S values calculated analytically with the help of Equation ( 20) and those acquired from the FEA results by Equation ( 15) are 0.13%, 0.17%, 0.59%, 0.19%, and 0.26% (1.46%, 1.74%, 2.83%, 2.45%, and 1.97% for NTs with D n ≲ 1.5 nm), for the SWBNNTs, SWAlNNTs, SWGaNNTs, SWInNNTs, and SWTlNNTs, respectively. It can be assumed that Equation (20) leads to an accurate evaluation of the surface shear modulus of the 13th group atom-nitride nanotubes across the entire range of the NT diameters considered in the current study, although the error obtained for NTs with D n up to 1.5 nm is slightly higher. The G S values calculated by Equation (20) are shown in Figure 9b as a function of the bond length, a A13−N .…”
Section: Surface Shear Modulus and Poisson's Ratiomentioning
confidence: 90%
“…SWTlNNTs, respectively. It can be assumed that Equation (20) leads to an accurate ation of the surface shear modulus of the 13th group atom-nitride nanotubes acro entire range of the NT diameters considered in the current study, although the err tained for NTs with D n up to 1.5 nm is slightly higher. The G S values calculated by tion (20) are shown in Figure 9b The G S results available in the literature are scarce, even for the case of SWB and show considerable discrepancy, as seen in Figure 10a,b.…”
Section: Surface Shear Modulus and Poisson's Ratiomentioning
confidence: 90%
See 3 more Smart Citations