2007
DOI: 10.1109/apex.2007.357583
|View full text |Cite
|
Sign up to set email alerts
|

A Direct Peak DC-link Boost Voltage Control Strategy in Z-Source Inverter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
37
0
3

Year Published

2010
2010
2023
2023

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 61 publications
(40 citation statements)
references
References 4 publications
0
37
0
3
Order By: Relevance
“…There are four methods for controlling the ZSI dc-link voltage, which are: capacitor voltage control [12]- [19], indirect dc-link voltage control [19], [20], direct dc-link control [21], [22] and unified control [23]. Table 3, presents a review of the above mentioned control methods with their drawbacks.…”
Section: Zsi DC Link Voltage Controlmentioning
confidence: 99%
“…There are four methods for controlling the ZSI dc-link voltage, which are: capacitor voltage control [12]- [19], indirect dc-link voltage control [19], [20], direct dc-link control [21], [22] and unified control [23]. Table 3, presents a review of the above mentioned control methods with their drawbacks.…”
Section: Zsi DC Link Voltage Controlmentioning
confidence: 99%
“…Therefore, the ZSI can buck and boost voltage to a desired output voltage that is greater than the available DC bus voltage. The approaches to control constantly and stably the output voltage of the ZSI, many studies such as modified SVM (space vector modulation) method under d-q coordinate transformation [3] also the calculation method of the boost factor and switching duration time by using PID control [4][5] have been done. Although all of them have showed a good performance but there are still so many problems that requires the complex control algorithm and the circuit for sensing the three-phase output voltages.…”
Section: Introductionmentioning
confidence: 99%
“…Such a pulse voltage introduces difficulty in detecting its peak value directly. A peak value sensing circuit is introduced in [8], and then a direct PDV controller is designed based on it. The additional sensing circuit remains to be carefully designed and may increase the complexity of the design.…”
Section: Introductionmentioning
confidence: 99%
“…For ZSIs, the control of dc-link stage is a key point while the control of ac side is similar to that in voltage-source inverter, therefore the controller design is focused on how to control the dc-link voltage. Existing control strategies of ZSIs including the following two types: the Z-source capacitor voltage (ZCV) control [7] and the peak dc-link voltage (PDV) control [8][9]. For ZCV control strategy, the capacitor voltage is controlled to a constant value.…”
Section: Introductionmentioning
confidence: 99%