2015
DOI: 10.1016/j.saa.2015.04.026
|View full text |Cite
|
Sign up to set email alerts
|

A direct method of quantification of maximal chemisorption of 3-aminopropylsilyl groups on silica gel using DRIFT spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
9
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 33 publications
1
9
0
Order By: Relevance
“…The obtained results are in agreement with our previous results, employing a direct DRIFT method and carbon elemental analysis [27]. The indirect method for determination of the maximal amount of the chemisorbed APS fragments on the silica gel surface employs easier experimental methodology than the direct DRIFT technique in the sense that it does not require inert conditions during the sample preparation for the IR recording and for the recording itself.…”
Section: Introductionsupporting
confidence: 91%
See 3 more Smart Citations
“…The obtained results are in agreement with our previous results, employing a direct DRIFT method and carbon elemental analysis [27]. The indirect method for determination of the maximal amount of the chemisorbed APS fragments on the silica gel surface employs easier experimental methodology than the direct DRIFT technique in the sense that it does not require inert conditions during the sample preparation for the IR recording and for the recording itself.…”
Section: Introductionsupporting
confidence: 91%
“…Using two samples with higher starting w/w APTMS of 25.16 % and 29.80 %, the average w/w APTMS value at maximum APS chemisorptions was found to be 19.04 %. According to the BET surface value of 589 m 2 /g for the silica gel [27,29], the calculated adsorption for APS was found to be 2.23 μmol m -2 . This value is the same as the one obtained by the direct DRIFT method 2.23 μmol m -2 and very close to the one obtained from elemental analysis 2.22 μmol m -2 [27].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…It is important that the specular reflectance is reduced to a minimum because it distorts the DRIFT spectrum and lowers the band intensities [47]. During the last years, it has become the most effective technique for studying the processes taking place at the gas-solid interface [48].…”
Section: Applications Of Molecular Spectroscopy To Current Research Imentioning
confidence: 99%