2020
DOI: 10.1007/s10337-019-03853-3
|View full text |Cite
|
Sign up to set email alerts
|

A Dilute-and-Shoot LC–MS/MS Method for Urinary Glyphosate and AMPA

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 16 publications
(12 citation statements)
references
References 17 publications
0
6
0
Order By: Relevance
“…Further studies are needed to explore the possibility of analyzing histamine with relatively recent extraction methods, such as “Quick, Easy, Cheap, Effective, Rugged and Safe” (QuEChERS), which is used for the determination of polar and nonpolar compounds [ 7 , 47 ] and “dilute and shoot”, which is useful to reduce the waste of solvents during analysis [ 48 , 49 ], in accordance with the principles of GAC.…”
Section: Resultsmentioning
confidence: 99%
“…Further studies are needed to explore the possibility of analyzing histamine with relatively recent extraction methods, such as “Quick, Easy, Cheap, Effective, Rugged and Safe” (QuEChERS), which is used for the determination of polar and nonpolar compounds [ 7 , 47 ] and “dilute and shoot”, which is useful to reduce the waste of solvents during analysis [ 48 , 49 ], in accordance with the principles of GAC.…”
Section: Resultsmentioning
confidence: 99%
“…The analytical technique described by Jaikwang et al was used for glyphosate analysis [ 21 ] using liquid chromatography-tandem mass spectrometry (LC–MS/MS). The system used was the Agilent 1290 Infinity high-performance liquid chromatography system coupled with an Agilent 6460 triple quadrupole mass spectrometer and electrospray ionization (Agilent Technologies, Inc., Palo Alto, CA, USA).…”
Section: Methodsmentioning
confidence: 99%
“…The accuracy and precision were between 86–105%. The analytical limit of quantification (LOQ) of this method was 5 g/L, with a 2.5 g/L limit of detection (LOD) [ 21 ]. The samples with concentrations less than LOD were given the value LOD/square root 2 [ 22 ].…”
Section: Methodsmentioning
confidence: 99%
“…malathion (boiling point 156 °C), dimethoate (boiling point 117 °C), both being challenging candidates for extraction from matrix, liquid chromatography and ESI-MS by virtue of being semi volatile. Also studied were glyphosate, a widely used water soluble, amphoteric, highly polar broad spectrum herbicide and its main metabolite aminomethylphosphonic acid (AMPA) a highly polar, amphoteric, difficult to retain on column compound (Jaikwang, 2020). The vary fact that we were able to grately suppress and control formation of metal ion adducts in such a hetrogenous group of compounds scattered all over the domain of organic chemistry itself speaks of the robustness, efficiency usefulness of the technique developed by us as discussed subsequently.…”
Section: Resultsmentioning
confidence: 99%