High accuracy impedance measurements are performed with coaxial transformer bridges, whose conventional design allow the comparison of like impedances-pure resistors or capacitors. Here we present a current comparator bridge suited for the measurement of impedances of arbitrary magnitudes and phase angles. The bridge has three arms, to connect the impedance under measurement and two calibrated standards. The bridge is digitally assisted and its operation is based on a polyphase digital sine wave synthesizer. To allow the measurement of mid-to low-impedance magnitudes, the bridge network and the balancing procedure are designed to approximate the four terminal-pair definition of the three impedance standards. The bridge has been extensively tested with conventional impedance standards and custom designed phase standards. The relative base accuracy is in the 10 −5-10 −6 range at kHz frequency. Index Terms-Impedance measurement, bridge circuits, electromagnetic devices, precision measurements. This activity has been partially funded by the Progetto Premiale MIUR-INRIM P6-2012, Implementation of the new International System (SI) of Units. The work has been carried out within the European Metrology Research Programme (EMRP) SIB 53, Automated impedance metrology extending the quantum toolbox on electricity. The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union.