2013
DOI: 10.1016/j.microc.2012.07.010
|View full text |Cite
|
Sign up to set email alerts
|

A digital image-based micro-flow-batch analyzer

Abstract: This paper introduces for the first time the combination of digital images taken with a webcam and a microflow-batch analyzer as a novel strategy for implementing quantitative chemical analysis. The digital imagebased micro-flow-batch analyzer (DIB-μFBA) was formed using urethane-acrylate resin, glass slides and ultraviolet lithography. The glass slides were used as sealant layers on both sides of the substrate urethane-acrylate and provide the necessary transparency to the microsystem to conduct studies using… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0
1

Year Published

2013
2013
2023
2023

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 46 publications
(11 citation statements)
references
References 31 publications
0
10
0
1
Order By: Relevance
“…If is the velocity value obtained from cross-correlation, and the value of load cell attached at the base of the known length channel -observing a steady flow is . The equation 5 can compute the average mass flow rate at a crosssection of the pipe (5) The equation is valid only for the steady state flow of the solid particles sliding along the bottom surface of the channel as a discrete dense phase material under gravity. If the particles pneumatically conveyed in air, they dispersed, and the chances of errors in load cell measurement are possible.…”
Section: Mass Flow Rate Measurementmentioning
confidence: 99%
See 1 more Smart Citation
“…If is the velocity value obtained from cross-correlation, and the value of load cell attached at the base of the known length channel -observing a steady flow is . The equation 5 can compute the average mass flow rate at a crosssection of the pipe (5) The equation is valid only for the steady state flow of the solid particles sliding along the bottom surface of the channel as a discrete dense phase material under gravity. If the particles pneumatically conveyed in air, they dispersed, and the chances of errors in load cell measurement are possible.…”
Section: Mass Flow Rate Measurementmentioning
confidence: 99%
“…Although hazardous to health by radiation leakage and require proper shielding, the results of radiometric methods are quite promising in the case of high concentration of solid particles. [4], [5]. If an economical, trustworthy, simple, and robust solution is required, the electrostatic and capacitive sensors are the best choices.…”
Section: Introductionmentioning
confidence: 99%
“…Although, there are published works on the use of webcam cameras for colorimetric detection in flow analysis systems (Rodrigues and Lapa, 2010;Wongwilai et al, 2010;Andrade et al, 2013;Lima et al, 2013;Lima et al, 2014), thus far there has been no report of their use in a remotely controlled flow system.…”
Section: Introductionmentioning
confidence: 99%
“…Reagent mediated analyses have been extensively studied in which digital images describing color development of one-shot sensing spots were evaluated [4,6,8,10]. There has also been work done using digital images of solutions based on their spectral properties [11][12][13][14][15][16].…”
Section: Introductionmentioning
confidence: 99%