A didactic procedure for designing power oscillation dampers of FACTS devices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
13
0
2

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(16 citation statements)
references
References 14 publications
0
13
0
2
Order By: Relevance
“…In conventional power plant for SGs, the PSS is implemented for the auxiliary controller to damp out the oscillations and enhance the LFOs in the system. Similarly, this PSS is also designed for DFIG-based WTG using anyone of the analyses such as trial and error method, frequency-domain analysis [20], residue analysis [9] and based on optimisation [12] to provide additional mechanical damping. It is necessary that the damped signals with a stable power are needed for the DFIG-WTG when it is connected to the grid.…”
Section: Modelling Of Pssmentioning
confidence: 99%
See 2 more Smart Citations
“…In conventional power plant for SGs, the PSS is implemented for the auxiliary controller to damp out the oscillations and enhance the LFOs in the system. Similarly, this PSS is also designed for DFIG-based WTG using anyone of the analyses such as trial and error method, frequency-domain analysis [20], residue analysis [9] and based on optimisation [12] to provide additional mechanical damping. It is necessary that the damped signals with a stable power are needed for the DFIG-WTG when it is connected to the grid.…”
Section: Modelling Of Pssmentioning
confidence: 99%
“…where n is the number of lead-lag blocks (n = 2), ΔX wf(pss) is the washout filter output, T w is the time constant of the washout filter, ΔX LL(pss) is the lead-lag output, T 1 -T 4 are the time constants of the compensator, V (pss) is the output of the voltage stabiliser, ω (pss) is the output of the rotor speed, K (pss) is the proportional gain, ϕ is the phase compensation and ω n is the critical frequency of oscillation for the input signal calculated [20]. The design of the generator rotor speed is same as above by replacing the v pss with ω pss .…”
Section: Model Of Voltage and Rotor Speed Stabilisermentioning
confidence: 99%
See 1 more Smart Citation
“…A regional pole constraint is also added and a quadratic performance index has been minimized for only the nominal plant. Flexible alternating current transmission (FACTS) devices equipped with a PSS provide more efficient oscillation damping (Ayres et al, 2010). In Farsangi et al (2003), a mixed H 2 /H N with regional pole placement is used to design FACTS-based damping controllers.…”
Section: Introductionmentioning
confidence: 99%
“…Yapılandırılan bu model Şekil 3'te gösterilmiştir. POD tarafından eklenen sönümleme miktarını belirler ve faz kompansatör blokları, giriş sinyalinin uygun faz gecikme telafisini sağlar[12].GSS parametrelerinin ayarlanması için birkaç tasarım yöntemi kullanılabilir. En popüler olanları sistemin frekans tepkisi, özdeğer hassasiyeti ve frekans-özdeğer birleşmesine dayanır.…”