2006
DOI: 10.1385/ncc:5:2:134
|View full text |Cite
|
Sign up to set email alerts
|

A Device for Fast Mechanical Clot Retrieval From Intracranial Arteries (Phenox Clot Retriever)

Abstract: The phenox clot retriever, a flexible microfilament pattern, might be a useful supplement to the repertoire of currently available devices for endovascular intracranial thrombectomy.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
31
0

Year Published

2009
2009
2014
2014

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 40 publications
(31 citation statements)
references
References 9 publications
0
31
0
Order By: Relevance
“…The smallest version is capable of recanalizing vessel diameters well below 2 mm such as the distal MCA branches. 54 This device became available for the treatment of patients with acute ischemic stroke in Europe in October 2006.…”
Section: Ia Mechanical Approaches In Acute Ischemic Strokementioning
confidence: 99%
“…The smallest version is capable of recanalizing vessel diameters well below 2 mm such as the distal MCA branches. 54 This device became available for the treatment of patients with acute ischemic stroke in Europe in October 2006.…”
Section: Ia Mechanical Approaches In Acute Ischemic Strokementioning
confidence: 99%
“…This device is also known to cause vasospasm and vessel dissection. Reported recanalisation rates for loop-shaped tools, a corkscrew-shaped nitinol coil (Merci Retriever, Concentric Inc., CA) and a nitinol basket are in the range of 50% [13]. In phase 1 of the Mechanical Embolus Removal in Cerebral Ischemia (MERCI) trial, which included 28 patients, successful recanalisation with mechanical embolectomy was achieved in 12 (43%) patients, with additional intra-arterial tPA in 18 (64%) patients [14].…”
Section: Discussionmentioning
confidence: 99%
“…The Phenox CRC device is a modification of the Phenox pCR device, 8,14,15 adding an additional self-expanding nitinol cage at the proximal end of a brushlike device. In the present study, the novel device was found to be effective for recanalization with an overall complete recanalization rate (TICI/ TIMI 3) of 86.7%.…”
Section: Discussionmentioning
confidence: 99%
“…8,14,15 It consists of a highly flexible nitinol/platinumalloy core wire compound. This wire compound holds radially oriented polyamide microfilaments and is marked by radiodense markers on the proximal and distal ends.…”
Section: Thrombectomy Devicementioning
confidence: 99%
See 1 more Smart Citation