2021
DOI: 10.1016/j.buildenv.2021.108230
|View full text |Cite
|
Sign up to set email alerts
|

A critical review of passive condensation prevention for radiant cooling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
0
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 37 publications
(4 citation statements)
references
References 81 publications
0
0
0
Order By: Relevance
“…*evaporative cooling and *radiant cooling did not appear in both the co-occurrence network and multidimensional scaling maps. Both passive cooling methods considered materials, structures, and installation positions [16][17][18][19][20][62][63][64]; thus, it is difficult to connect specific words in the co-occurrence network. Interestingly, radiant and evaporative were among the 200 most frequently used words.…”
Section: Constructing Coding Rulesmentioning
confidence: 99%
“…*evaporative cooling and *radiant cooling did not appear in both the co-occurrence network and multidimensional scaling maps. Both passive cooling methods considered materials, structures, and installation positions [16][17][18][19][20][62][63][64]; thus, it is difficult to connect specific words in the co-occurrence network. Interestingly, radiant and evaporative were among the 200 most frequently used words.…”
Section: Constructing Coding Rulesmentioning
confidence: 99%
“…In addition, calculating the minimum wall temperature is critical to determining the minimum allowable humidity level of the zone air to avoid condensation on the wall surface. Condensation also reduces the effectiveness of radiant cooling systems [45]. Moreover, thermal comfort can be impacted by the uniformity of the surface temperature.…”
Section: Water Outlet and Average Wall Temperaturesmentioning
confidence: 99%
“…In addition, a radiant cooling system combined with a mechanical ventilation system can also effectively avoid the shortcomings of traditional air-conditioning systems, such as bacterial growth and loud noise [13][14][15][16]. Normally, the radiant cooling system is divided into three types according to the installation location: ceiling cooling (CC), floor cooling (FC) and wall cooling (WC) [17][18][19]. The cooling capacity per unit area of CC is up to 100 W/m 2 , which is more suitable for modern buildings with large, sensible cooling loads compared to FC and WC [20][21][22][23][24].…”
Section: Introductionmentioning
confidence: 99%