2004
DOI: 10.1016/j.jelechem.2003.12.010
|View full text |Cite
|
Sign up to set email alerts
|

A correlation study between the conformation of the 1,4-dithiane SAM on gold and its performance to assess the heterogeneous electron-transfer reactions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
7
0

Year Published

2007
2007
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(9 citation statements)
references
References 37 publications
2
7
0
Order By: Relevance
“…Table 1 shows that the value of H decreases with the immersion time, suggesting that the adsorption of the pyS on gold leads to a partially blocked surface implying that pyS is not a continuous film and that the gold surface is not uniformly accessible. This analysis is in close agreement with previous reports in the literature about the adsorption of the 1,4-dithiane on gold surface studied by hydrodynamic impedance technique [20].…”
Section: Resultssupporting
confidence: 93%
See 1 more Smart Citation
“…Table 1 shows that the value of H decreases with the immersion time, suggesting that the adsorption of the pyS on gold leads to a partially blocked surface implying that pyS is not a continuous film and that the gold surface is not uniformly accessible. This analysis is in close agreement with previous reports in the literature about the adsorption of the 1,4-dithiane on gold surface studied by hydrodynamic impedance technique [20].…”
Section: Resultssupporting
confidence: 93%
“…Previous cyclic voltammetric results [20] showed that the presence of the 1,4-dithiane species on the Au surface strongly inhibited the Fe 2+ /Fe 3+ reaction with respect to that on the bare gold electrode after a long modification time (t > 15 h). These previous results are evidences that electron transfer reaction for the probe molecule occurs within the layer defects and at the uncovered electrode surface.…”
Section: Resultsmentioning
confidence: 95%
“…The LOD ranges from 10 −8 M in the case of PYR and TP to 10 −10 M for COR. These LODs are similar to those reported by employing chromatographic and fluorimetric methods [39][40][41][42], with the additional advantage that no pre-concentration step was necessary. COR represents a special case.…”
Section: Calixarenessupporting
confidence: 82%
“…The membrane resistance values, R m , were extracted from fitted data (Table 3) which are 8292 and 37120 Ωcm 2 for bare Au-electrode and mixed modified Auelectrode, respectively. The values of the fractional coverage area of the SAM monolayer (θ) can be calculated from the impedance diagrams using [36] …”
Section: Impedance Measurementmentioning
confidence: 99%