2017 IEEE 18th Workshop on Control and Modeling for Power Electronics (COMPEL) 2017
DOI: 10.1109/compel.2017.8013415
|View full text |Cite
|
Sign up to set email alerts
|

A control scheme for utilizing energy storage of the modular multilevel converter for power oscillation damping

Abstract: Abstract-This paper presents a control scheme that utilizes energy storage of the Modular Multilevel Converter (MMC) for Power Oscillation Damping (POD) service. Such a service is used to enhance grid stability by providing damping power in the electromechanical (0.2-2Hz) dynamics range. The scheme uses compensated modulation with average energy control. The aforementioned service comes at the cost of additional energy storage requirement for the MMC. A worst case estimate of this additional capacity, together… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
18
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5
2

Relationship

3
4

Authors

Journals

citations
Cited by 7 publications
(19 citation statements)
references
References 10 publications
(15 reference statements)
1
18
0
Order By: Relevance
“…wind gusts and tower shadowing, as studied in [8]. Possibly, these capabilities could also be used for other purposes such as power oscillation damping, improve voltage behaviour, increasing the life span of batteries by eliminating ripple or providing initial frequency response and system inertia [22]- [25].…”
Section: A the Internal Storage Contribution Of The MMCmentioning
confidence: 99%
“…wind gusts and tower shadowing, as studied in [8]. Possibly, these capabilities could also be used for other purposes such as power oscillation damping, improve voltage behaviour, increasing the life span of batteries by eliminating ripple or providing initial frequency response and system inertia [22]- [25].…”
Section: A the Internal Storage Contribution Of The MMCmentioning
confidence: 99%
“…where i dc is the dc line current and c dc is the equivalent dc side capacitance in per-unit. Finally, the ac current dynamics is given by (6) where ω is the fundamental frequency in rad/s and v gdq is the grid voltage at the Point of Commom Coupling (PCC) in dq domain. l ac and r ac are the equivalent ac side inductance and resistance in per-unit to the ac base values.…”
Section: B Average Arm Energy Modelmentioning
confidence: 99%
“…Energy storage capacity inherently available in the HVDC converters, particularly the Modular Multilevel Converters (MMCs), can be used to mitigate this problem. It has been shown in literature [5], [6] that sub-module capacitors in the MMC can effectively provide the required power injection for the case of POD. Such schemes can also be extended to other type of services.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations