2005
DOI: 10.1016/j.jmr.2005.05.009
|View full text |Cite
|
Sign up to set email alerts
|

A continuous phase-modulated approach to spatial encoding in ultrafast 2D NMR spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
58
0

Year Published

2008
2008
2014
2014

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 45 publications
(58 citation statements)
references
References 20 publications
0
58
0
Order By: Relevance
“…However, the application of a short gradient can be useful to compensate for experimental errors or to set the echoes at the desired position. Tal et al [9] proposed another method leading to a continuous phase encoding, described in Fig. 1b.…”
Section: Comparison Of Different Continuous Phase-encoding Schemesmentioning
confidence: 99%
See 2 more Smart Citations
“…However, the application of a short gradient can be useful to compensate for experimental errors or to set the echoes at the desired position. Tal et al [9] proposed another method leading to a continuous phase encoding, described in Fig. 1b.…”
Section: Comparison Of Different Continuous Phase-encoding Schemesmentioning
confidence: 99%
“…Unfortunately, this method involves an amplitude modulation which is incompatible with phasemodulated techniques such as COSY [1] or J-resolved spectroscopy [8]. Different alternatives were then proposed [9][10][11] to obtain a phase-modulated encoding in order to circumvent these limitations.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…This advantage can be achieved by replacing the usual incrementation of the t 1 -evolution interval by a spatial encoding of the phases across the sample, while decoding is performed with the help of alternating gradients applied during the detection period. The spatial encoding can be greatly improved by using adiabatic frequency-modulated pulses [7][8][9]. This new technique has been successfully combined with liquid chromatography [10] and with methods to increase the polarization of nuclear spins [11].…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, it leads to the appearance of undesirable ''ghost peaks" 18 in the indirect domain. Consequently, this discrete excitation scheme was replaced by several continuous encoding patterns [19][20][21][22] relying on the combination of continuous frequency swept pulses applied during a bipolar gradient. The most efficient approach in terms of resolution and sensitivity is probably that proposed by Pelupessy ( Figure 1S, supplementary material), 20 where spatial encoding is carried out in a constant-time manner through the application of two chirp pulses concomitantly with a bipolar gradient pair (G e ).…”
Section: Introductionmentioning
confidence: 99%