A computer-based biomechanical analysis of the three-dimensional motion of cementless hip prostheses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

5
12
1

Year Published

1993
1993
2017
2017

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 32 publications
(18 citation statements)
references
References 4 publications
5
12
1
Order By: Relevance
“…Micromotion has already been measured on cadaveric femurs, but only on a limited number of simultaneous locations. The values of micromotion reported here are compatible with other cadaveric measurements (Walker et al, 1987;Gilbert et al, 1992;Buhler et al, 1997;Britton et al, 2004). Although the comparison is not always easy because of different techniques and loading conditions, most cadaveric studies report maximal amplitude of micromotion and subsidence of about 100 mm, with higher values on the medial than on the lateral side.…”
Section: Discussionsupporting
confidence: 78%
See 1 more Smart Citation
“…Micromotion has already been measured on cadaveric femurs, but only on a limited number of simultaneous locations. The values of micromotion reported here are compatible with other cadaveric measurements (Walker et al, 1987;Gilbert et al, 1992;Buhler et al, 1997;Britton et al, 2004). Although the comparison is not always easy because of different techniques and loading conditions, most cadaveric studies report maximal amplitude of micromotion and subsidence of about 100 mm, with higher values on the medial than on the lateral side.…”
Section: Discussionsupporting
confidence: 78%
“…This measure is usually divided into subsidence (Steimer et al, 2006) and micromotion (Baleani et al, 2000). Recent studies are mainly using linear variable differential transducers (LVDT's) (Walker et al, 1987;Gilbert et al, 1992;Buhler et al, 1997;Britton et al, 2004;Cristofolini et al, 2007;Gheduzzi and Miles, 2007. LVDT however do not really measure the local relative micromotion between the stem and the bone, but also include bone deformation between the device fixation and the measurement site.…”
Section: Introductionmentioning
confidence: 99%
“…We have also verified that this error was sufficient to detect detrimental micromotions, and their location. The maximal amplitude of micromotion was consistent with typical reported values in the literature (Walker et al, 1987;Gilbert et al, 1992;Buhler et al, 1997;Britton et al, 2004).…”
Section: Discussionsupporting
confidence: 80%
“…However, even if the problem is clearly observed and partly quantified, measurement methods are not fully satisfactory. Most of the studies are using linear variable differential transducers (LVDT's) (Walker et al, 1987;Gilbert et al, 1992;Buhler et al, 1997;Britton et al, 2004;Gheduzzi and Miles, 2007) which do not really measure the local relative micromotion between the stem and the bone, but also include bone deformation between the device fixation and the measurement site. Besides, the number of simultaneous measurement points is limited to 1 or 2, with a reported maximum of 4 (Cristofolini et al, 2003).…”
Section: Introductionmentioning
confidence: 99%
“…For this purpose the micromotions between the implant and the artificial bone, crucial for bone ingrowths [14][15][16] were recorded. Additionally the results should be compared with the literature.…”
Section: Introductionmentioning
confidence: 99%