2001
DOI: 10.1007/3-540-45468-3_41
|View full text |Cite
|
Sign up to set email alerts
|

A Computer-Assisted Robotic Ultrasound-Guided Biopsy System for Video-Assisted Surgery

Abstract: Current ultrasound-guided biopsy procedures used in videoassisted surgery suffer from limitations due to difficult triangulation and manual positioning of the biopsy needle. We present a prototype computer-assisted robotic system for needle positioning that operates in a synergistic way with the clinician. The performance of the system in terms of positioning accuracy and execution time is assessed. Results suggest suitability for clinical use.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
31
0

Year Published

2005
2005
2023
2023

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 29 publications
(32 citation statements)
references
References 8 publications
1
31
0
Order By: Relevance
“…Ultrasonography is a popular imaging modality for visualizing percutaneous body structures, since it is cheap, non‐invasive, real‐time and with no known long‐term side‐effects. Megali et al (52) describe one of the earliest attempts to guide a robot using two‐dimensioanl (2D) ultrasound guidance for biopsy procedures. Their system consisted of a manipulator mounted with a biopsy needle at its end‐effector, an ultrsound probe and a 3D localizer.…”
Section: Resultsmentioning
confidence: 99%
“…Ultrasonography is a popular imaging modality for visualizing percutaneous body structures, since it is cheap, non‐invasive, real‐time and with no known long‐term side‐effects. Megali et al (52) describe one of the earliest attempts to guide a robot using two‐dimensioanl (2D) ultrasound guidance for biopsy procedures. Their system consisted of a manipulator mounted with a biopsy needle at its end‐effector, an ultrsound probe and a 3D localizer.…”
Section: Resultsmentioning
confidence: 99%
“…In the platform, an industrial robot (Samsung FARA AT2) has been integrated to provide active surgical assistance and accurate positioning during intervention (27). The robot reference system has been calibrated with the global reference system (given by the optical localization system), so that the robot can be moved along planned trajectories in a closed loop with the surgical navigator.…”
Section: Robot Armmentioning
confidence: 99%
“…al. 13 . This system was considered synergistic in that the procedure had both robotic and manual input components.…”
Section: Introductionmentioning