1990
DOI: 10.1016/0300-9629(90)90664-e
|View full text |Cite
|
Sign up to set email alerts
|

A computer-aided physiological monitoring system for continuous, long-term recording of cardiac activity in selected invertebrates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
97
0
3

Year Published

2000
2000
2018
2018

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 175 publications
(101 citation statements)
references
References 5 publications
1
97
0
3
Order By: Relevance
“…levels were measured at the start (120 -130 %) and end (112-120 %) of each trial to ensure that individuals were not exposed to hypoxic 185 conditions. Cardiac activity was recorded using an infrared phototransducer attached to the carapace using cyanoacrylate glue to facilitate heart rate monitoring using the ComputerAided Physiological MONitoring system (CAPMON) (Depledge & Andersen 1990 …”
Section: Foraging Behaviour and Heart Rate Monitoringmentioning
confidence: 99%
“…levels were measured at the start (120 -130 %) and end (112-120 %) of each trial to ensure that individuals were not exposed to hypoxic 185 conditions. Cardiac activity was recorded using an infrared phototransducer attached to the carapace using cyanoacrylate glue to facilitate heart rate monitoring using the ComputerAided Physiological MONitoring system (CAPMON) (Depledge & Andersen 1990 …”
Section: Foraging Behaviour and Heart Rate Monitoringmentioning
confidence: 99%
“…Following urine extraction, heart rate measurements were performed on shore crabs by use of the non-invasive CAPMON system (Depledge and Andersen, 1990). Heart rate measurements were performed on individuals in 2 L aquaria (using water collected from each site); sensors were glued to the carapace above the heart and, after 30 min acclimation, cardiac activity (at rest) was recorded for 30 min as (as employed previously by Dissanayake et al, 2008b).…”
Section: Shore Crab Physiological Assessmentmentioning
confidence: 99%
“…In order to minimise the complexity of this method, Depledge and Anderson [19] instead developed the photoplethysmographic technique for non-invasive monitoring of cardiac activity in arthopods, which is utilised in the present study. Through this method an IR light-emitting diode (LED) coupled axially with a phototransistor (CNY-70 reflex-optocoupler, Vishay Semiconductor GmbH) is used to measure movements of internal organs.…”
Section: Use Of Heartbeat Sensors Under Pressurementioning
confidence: 99%