2014
DOI: 10.7863/ultra.33.1.83
|View full text |Cite
|
Sign up to set email alerts
|

A Computer‐Aided Diagnostic Algorithm Improves the Accuracy of Transesophageal Echocardiography for Left Atrial Thrombi

Abstract: A Single-Center Prospective Study trial fibrillation (AF) is the most common supraventricular arrhythmia, and if it persists for more than 48 hours, it predisposes the patient to develop a thrombus in the left atrium (LA)/left atrial appendage (LAA). 1 With their propensity for sysLin Sun, MD, Yang Li, MD, Ying Tao Zhang, PhD, Jing Xia Shen, MMed, Feng Hua Xue, MMed, Heng Da Cheng, PhD, Xiu Fen Qu, PhD, MD Received March 10, 2013, Objectives-We investigated whether transesophageal echocardiography (TEE) a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
15
0
2

Year Published

2018
2018
2021
2021

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(18 citation statements)
references
References 25 publications
0
15
0
2
Order By: Relevance
“…43 There were several limitations to this study that merit discus- No similar to that reported by other investigators. Interestingly, beyond a direct relationship be- The addition of D-dimer and other risk factors will help to detect these patients.…”
Section: Discussionmentioning
confidence: 61%
See 1 more Smart Citation
“…43 There were several limitations to this study that merit discus- No similar to that reported by other investigators. Interestingly, beyond a direct relationship be- The addition of D-dimer and other risk factors will help to detect these patients.…”
Section: Discussionmentioning
confidence: 61%
“…Identifying these patients is crucial, as it would alter their subsequent therapy from antiplatelet to anticoagulation, which is known to be much more effective in reducing subsequent thromboembolic events. 43 There were several limitations to this study that merit discus- No similar to that reported by other investigators. Third, though our data were essentially complete for our major values five patients with negative clot and the positive D-dimer level did not have a complete hematologic WBC profile, which could have obscured these results.…”
Section: Discussionmentioning
confidence: 61%
“…42 Então, aplica-se a radiação estereotáxica, tratando a arritmia, com mínimo de dano possível ao tecido normal 45 e com tempo de tratamento em média menor que 20 minutos. 45 Essa técnica tem como população alvo pacientes com cardiomiopatia, pois é mais difícil identificar com precisão o substrato da taquiarritmia na ablação por cateter para taquicardia ventricular nesse grupo de pacientes, uma vez que esse substrato tem grande extensão não passível de ablação efetiva ou é inacessível pelas tecnologias atuais e, por isso, o procedimento com cateter está associado a altas taxas de recorrência, complicações e pior prognóstico em relação à IC e morte súbita. 46 Desta forma, para o grupo de cardiomiopatas, o fato da ablação extracorpórea apresentar-se como uma possibilidade de tratamento significa grande avanço terapêutico.…”
Section: Ablação Extracorpóreaunclassified
“…44 Similarly, another meta-analysis comparing deep learning tools with human image interpretations for any disease showed that the AI tools were equivalent, if not superior, to human interpretations. 45 However, these results must be interpreted in the context that the AI models were run on complete datasets, where the investigational testing and adverse patient outcomes had already happened. This retrospective validation is not proof of the algorithms' prospective efficacy and ultimate usability in altering patient outcomes.…”
Section: Impact and Intended Usage Domainmentioning
confidence: 99%
See 1 more Smart Citation