A Comprehensive Strategy for Power Quality Improvement of Multi-Inverter-Based Microgrid With Mixed Loads

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
14
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 39 publications
(15 citation statements)
references
References 9 publications
0
14
0
Order By: Relevance
“…The controller includes voltage/current control loops and droop control method. If the link impedance and output impedance are considered inductive and the equivalent circuit for two inverters in parallel are shown in Figure 3, the active and reactive power injected to the bus by every unit are expressed as follows [31]:…”
Section: Network-based Control Methods For Inverter Parallel Operationmentioning
confidence: 99%
See 1 more Smart Citation
“…The controller includes voltage/current control loops and droop control method. If the link impedance and output impedance are considered inductive and the equivalent circuit for two inverters in parallel are shown in Figure 3, the active and reactive power injected to the bus by every unit are expressed as follows [31]:…”
Section: Network-based Control Methods For Inverter Parallel Operationmentioning
confidence: 99%
“…r is the equivalent resistance and n X is the equivalent inductive reactance for the n th inverter. Considering a small phase difference between E n and U, it can be seen from Equations (1) and (2) that the active P n is strongly dependent on the power angle φ n , while the reactive power is mainly influenced by the amplitude difference E n -U [31]. Consequently, most wireless load sharing controllers introduce artificial droops into the output voltage reference.…”
Section: Network-based Control Methods For Inverter Parallel Operationmentioning
confidence: 99%
“…The accuracy and precision of phase tracking greatly affect the performance of grid connected inverter. If the phase-locked is not accurate or the accuracy is not high enough, it will seriously affect the quality of the output power of the inverter, and even damage the electrical equipment under the jurisdiction of the microgrid system [9][10]. In the grid connected inverter, the d-q Synchronous Reference Frame PLL (SRF-PLL) is often used to collect the voltage amplitude, phase, frequency and other information.…”
Section: Phase-locked Loop (Pll) Technologymentioning
confidence: 99%
“…The PQ problems of multi inverter based micro grid is resolved by the aforesaid two strategies. Besides, the harmonic suppression control strategy is used for minimizing the harmonic components [8]. The PQ is improved by adding the improved Dynamic Voltage Restorer (DVR) and RLC link filter among the injection transformers with voltage source inverter.…”
Section: Introductionmentioning
confidence: 99%