“…Bone is the tissue with the greatest X-ray attenuation coefficient, while fat or adipose tissue attenuates the smallest amount of X-ray photons. The X-ray attenuation is measured in Hounsfield units (HU) with water having-by definition-a HU of 0 and air of −1000 [26]. The full formula for the calculation of the Hounsfield units is as follows:…”
Section: Computed Tomography (Ct)mentioning
confidence: 99%
“…Bone is the tissue with the greatest X-ray attenuation coefficient, while fat or adipose tissue attenuates the smallest amount of X-ray photons. The X-ray attenuation is measured in Hounsfield units (HU) with water having-by definition-a HU of 0 and air of −1000 [26]. The full formula for the calculation of the Hounsfield units is as follows:…”
Section: Computed Tomography (Ct)mentioning
confidence: 99%
“…The basis of spectral CT is that a CT scan can be decomposed into a set of multiple basis materials if the projection data is measured at different energies [4]. This leads to the development of dual-energy CT and multi-spectral CT [5]. Dual-energy refers to the use of two X-ray energies in scanning.…”
Section: Introductionmentioning
confidence: 99%
“…Estes aparelhos são chamados de dual energy CT (DECT). Atualmente existem três técnicas para se coletar dados de DECT [53].…”
Section: Tipos De Ct De Dupla Energia (Dect) E Ct Multienergiasunclassified
“…A primeira consiste em realizar dois escaneamentos do paciente em duas energias diferentes, uma após a outra ou com um tubo de raios X com mudança rápida de potencial do tubo de raios X. Os problemas desta técnica são que as imagens adquiridas em instantes diferentes podem apresentar problemas na correlação espacial (no caso de dois escaneamentos) e dificuldade em detectar e separar estes espectros de diferentes potenciais (para a mudança rápida de potencial do tubo) [53].…”
Section: Tipos De Ct De Dupla Energia (Dect) E Ct Multienergiasunclassified