2020
DOI: 10.1088/1361-6579/ab86d6
|View full text |Cite
|
Sign up to set email alerts
|

A comprehensive guideline for Bland–Altman and intra class correlation calculations to properly compare two methods of measurement and interpret findings

Abstract: The rapid emergence of new measurement instruments and methods requires personnel and researchers of different disciplines to know the correct statistical methods to utilize to compare their performance with reference ones and properly interpret findings. We discuss the often-made mistake of applying the inappropriate correlation and regression statistical approaches to compare methods and then explain the concepts of agreement and reliability. Then, we introduce the intraclass correlation as a measure of inte… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
57
0
2

Year Published

2020
2020
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 73 publications
(77 citation statements)
references
References 28 publications
(45 reference statements)
2
57
0
2
Order By: Relevance
“…In other words, a difference of 30 minutes or more between the two methods in the estimation of sleep parameters was considered of clinical significance. 19 , 20 In our study, the differences between the two devices fell within 30-minutes for all the parameters examined, except for WASO. Despite our findings, whether a 30-minute cutoff is acceptable for the interchangeable use of different sleep assessment modalities remains a question that needs to be answered from the clinical perspective.…”
Section: Discussionsupporting
confidence: 52%
See 1 more Smart Citation
“…In other words, a difference of 30 minutes or more between the two methods in the estimation of sleep parameters was considered of clinical significance. 19 , 20 In our study, the differences between the two devices fell within 30-minutes for all the parameters examined, except for WASO. Despite our findings, whether a 30-minute cutoff is acceptable for the interchangeable use of different sleep assessment modalities remains a question that needs to be answered from the clinical perspective.…”
Section: Discussionsupporting
confidence: 52%
“…Still, the deviations were not substantial (Q-Q plots can be found in Supplementary Figure 1 ). When analyzing Bland–Altman plots, we report the 95% limits of agreement, the minimal detectable change, and the minimal clinically important change as recommended by Haghayegh et al 19 The 95% limits of agreement between the two devices are defined as the mean difference ± 1.96 SD of the differences. The minimal detectable change is defined as the smallest amount of change in the score detected by a method, independent of measurement error.…”
Section: Methodsmentioning
confidence: 99%
“…With our study design, the Bland-Altman plot, as a measure of agreement, was appropriate to perform within-subject comparisons for the two methods. 43 The Kappa agreement between OSASS and technologist 1 and technologist 2 was 0.81 and 0.84, respectively, which suggests that OSASS is capable of reasonably estimating OSA severity. These results show that OSASS generalizes reasonably well.…”
Section: Dovepressmentioning
confidence: 87%
“…the absence of measurement error) [15]. Thus, in the present article "performance" refers to the qualities of a sleep tracker describing its measurement error (reliability and accuracy), as quantified by the agreement with a reference method [16,17].…”
Section: Step-by-step Guidelines For Testing the Performance Of Sleep-trackersmentioning
confidence: 99%