2018
DOI: 10.32598/bcn.9.10.200
|View full text |Cite
|
Sign up to set email alerts
|

A Comprehensive Comparison Between Steady-State Visual Evoked Potentials Frequency Estimation Methods in Brain-Computer Interface With The Minimum Number of EEG Channels

Abstract: Introduction: Brain-Computer Interface (BCI) systems provide a communication pathway between users and systems. BCI systems based on Steady-State Visually Evoked Potentials (SSVEP) are widely used in recent decades. Different feature extraction methods have been introduced in the literature to estimate SSVEP responses to BCI applications. Methods: In this study, the new algorithms, including Canonical Correlation Analysis (CCA), Least Absolute Shrinkage and Selection Op… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 25 publications
1
4
0
Order By: Relevance
“…Note that the classification accuracies of the L1-MCCA related methods with varied TWs were consistently higher than the CCA-related and PSDrelated methods. Our results are in agreement with previous research [30,41,42]. It has been reported that the L1-MCCA method can improve the classification accuracy of SSVEP-based BCI by optimizing the reference signal.…”
Section: Discussionsupporting
confidence: 93%
“…Note that the classification accuracies of the L1-MCCA related methods with varied TWs were consistently higher than the CCA-related and PSDrelated methods. Our results are in agreement with previous research [30,41,42]. It has been reported that the L1-MCCA method can improve the classification accuracy of SSVEP-based BCI by optimizing the reference signal.…”
Section: Discussionsupporting
confidence: 93%
“…Due to limitations associated with the connection mode between electrode and circuit and the claw-shaped dry electrode structure, the diameter of the active dry electrode is approximately 20 mm, which satisfies EEG acquisition design according to the 10-20 international system, but not the 10-10 international system. At the moment, many researchers are focusing on reducing the number of channels in EEG acquisition systems [ 35 , 36 , 37 ]. However, the high-density EEG and the accuracy of electrode position are still very important [ 38 , 39 ].…”
Section: Resultsmentioning
confidence: 99%
“…LASSO is considered a subject-independent technique since the penalty parameter that influences the LASSO performance is calculated offline by taking advantage of the SSVEP data from multiple subjects [ 41 ]. There has been recent research where the LASSO method was applied because of the ability to perform multichannel analysis for identifying SSVEP signal frequencies (e.g., [ 32 , 42 ]).…”
Section: Methodsmentioning
confidence: 99%
“…There has been recent research where the LASSO method was applied because of the ability to perform multichannel analysis for identifying SSVEP signal frequencies (e.g., [32,42]).…”
Section: Eeg Signal Recordings and Preprocessingmentioning
confidence: 99%