2012
DOI: 10.1371/journal.pone.0045607
|View full text |Cite
|
Sign up to set email alerts
|

A Comprehensive Assessment of the Precision and Agreement of Anterior Corneal Power Measurements Obtained Using 8 Different Devices

Abstract: PurposeTo comprehensively assess the precision and agreement of anterior corneal power measurements using 8 different devices.MethodsThirty-five eyes from 35 healthy subjects were included in the prospective study. In the first session, a single examiner performed on each subject randomly measurements with the RC-5000 (Tomey Corp., Japan), KR-8000 (Topcon, Japan), IOLMaster (Carl Zeiss Meditec, Germany), E300 (Medmont International, Australia), Allegro Topolyzer (Wavelight AG, Germany), Vista (EyeSys, TX), Pen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

9
71
3
2

Year Published

2014
2014
2021
2021

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 89 publications
(85 citation statements)
references
References 36 publications
9
71
3
2
Order By: Relevance
“…With low TRT (<0.31 D for repeatability and <0.16 D for reproducibility) and low CoV (not exceeding 0.26% for repeatability and 0.14% for reproducibility), we found a high precision of measurements for corneal power. It performs even better than the EyeSys (EyeSys Vision, Houston, Texas, USA) and Topolyzer (WaveLight Technologie AG, Erlangen, Germany) 7. Compared with the PCI, which measures the corneal curvature at 2.5 mm, statistically significant differences were observed, although the mean differences were small (0.09–0.13 D.) The results showed that the PCI provides slightly steeper K values than SS-OCT.…”
Section: Discussionmentioning
confidence: 89%
See 2 more Smart Citations
“…With low TRT (<0.31 D for repeatability and <0.16 D for reproducibility) and low CoV (not exceeding 0.26% for repeatability and 0.14% for reproducibility), we found a high precision of measurements for corneal power. It performs even better than the EyeSys (EyeSys Vision, Houston, Texas, USA) and Topolyzer (WaveLight Technologie AG, Erlangen, Germany) 7. Compared with the PCI, which measures the corneal curvature at 2.5 mm, statistically significant differences were observed, although the mean differences were small (0.09–0.13 D.) The results showed that the PCI provides slightly steeper K values than SS-OCT.…”
Section: Discussionmentioning
confidence: 89%
“…reports the repeatability and reproducibility data previously published for the latter device 7 12–18…”
Section: Discussionmentioning
confidence: 90%
See 1 more Smart Citation
“…Literatüre bakıldığında bu cihazların keratometrik analizdeki karşılaştırmasını yapan çeşitli yayınların bulunduğu görülmektedir. 1,7,[16][17][18] Ancak bahsedilen çalışmalar içinde Potec PRK-6000 otorefraktometresini dahil ederek IOLMaster ve Pentacam ile kıyas eden bir çalışmanın bulunmadığı görülmektedir. Bilgilerimiz ışığında literatürde ilk kez olmak üzere gerçekleştirdiğimiz bu çalışmamızda her üç cihazın da sadece korneal astigmatik değerler açısından birbiriyle uyumlu sonuçlar verdiği bulunmuştur.…”
Section: Katılım Kriterleriunclassified
“…[16][17][18][19] Çalışmamızda bu husus da irdelenmiş ve başta Pentacam olmak üzere her üç cihazın da oldukça tekrarlanabilir sonuçlar verdiği bulunmuştur.…”
Section: Katılım Kriterleriunclassified