2021
DOI: 10.1109/tpel.2021.3064302
|View full text |Cite
|
Sign up to set email alerts
|

A Comprehensive Assessment of Multiwinding Transformer-Based DC–DC Converters

Abstract: Multiwinding-Transfomer-based (MTB) DC-DC converter did emerge in the last 25 years as an interesting possibility to connect several energy systems and/or to offer higher power density because of the reduction of transformer core material and reduction of power converter stages. MTB DC-DC converters can be considered as an interesting compromise between non-modular and a modular DC-DC converter since they are themselves modular in the construction. This eventually leads to some fault-tolerant possibilities sin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
14
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
8
1
1

Relationship

1
9

Authors

Journals

citations
Cited by 43 publications
(14 citation statements)
references
References 59 publications
0
14
0
Order By: Relevance
“…The work in [23] demonstrated that a slight improvement in power density can be achieved in an electric machine by shifting from a three-phase design to a multi-threephase design. In addition to the advantages available at the machine level, the solution involving the use of a multiport dc-dc converter can offer a power density increase of up to 30% [25], rendering this latter solution even more interesting.…”
Section: Fig 8 Single DC Bus Epdsmentioning
confidence: 99%
“…The work in [23] demonstrated that a slight improvement in power density can be achieved in an electric machine by shifting from a three-phase design to a multi-threephase design. In addition to the advantages available at the machine level, the solution involving the use of a multiport dc-dc converter can offer a power density increase of up to 30% [25], rendering this latter solution even more interesting.…”
Section: Fig 8 Single DC Bus Epdsmentioning
confidence: 99%
“…As described before, the choice of the port inductance is critical in operation scenarios with large voltage deviations [29]. Therefore this approach is especially suitable for such scenarios to avoid high rms currents.…”
Section: B Choice Of Transformer Turns Ratio and Port Inductancesmentioning
confidence: 99%
“…According to the number of transformer winding, the existing isolated three-port dc-dc converters mainly include the single-transformer type and the two-transformer type [4][5][6][7][8][9][10][11][12][13][14]. The single-transformer converter presents a clear advantage regarding the increase of the power density and the system integration.…”
Section: Introductionmentioning
confidence: 99%