2013
DOI: 10.1259/dmfr/66925194
|View full text |Cite
|
Sign up to set email alerts
|

A comparison of the thresholding strategies of micro-CT for periodontal bone loss: a pilot study

Abstract: Objectives: Micro-CT provides three-dimensional details and has been widely used for biomedical assessments. This study aimed to determine the most appropriate threshold method for quantitatively assessing the dynamics of periodontal destruction. Methods: Inflammation was induced by submerging a silk ligature in the sulcus of the maxillary second molars of rats, and the animals were killed prior to ligature placement and after 7 and 21 days. The maxillae were examined for the bone resorptive activities by micr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
28
1
4

Year Published

2013
2013
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 36 publications
(33 citation statements)
references
References 25 publications
0
28
1
4
Order By: Relevance
“…Although in in vitro studies the linear regression coefficient was 96.9%, thereby demonstrating a high reliability of the volumetric measurements with CBCT data, the percentage of deviation was up to 18% (17,29). Therefore, in this study, reduction and enlargement of the radiolucency were determined when the volume of the radiolucency had been reduced or enlarged by 20% or more.…”
Section: Discussionmentioning
confidence: 80%
See 1 more Smart Citation
“…Although in in vitro studies the linear regression coefficient was 96.9%, thereby demonstrating a high reliability of the volumetric measurements with CBCT data, the percentage of deviation was up to 18% (17,29). Therefore, in this study, reduction and enlargement of the radiolucency were determined when the volume of the radiolucency had been reduced or enlarged by 20% or more.…”
Section: Discussionmentioning
confidence: 80%
“…Measurement of lesion volume on CBCT data in DICOM format (Digital Imaging and Communication in Medicine) was performed by using Amira 5.4.3 (Visage Imaging GmbH, Berlin Germany) software. Local thresholddetermining algorithm (17) with manual tracing intervention was used to plot out the border of the lesion and calculate the volume (18). The length and density of root canal filling were determined as previously described (19,20).…”
Section: Discussionmentioning
confidence: 99%
“…ICC values higher than 0.75 were considered to show good reliability and low CV demonstrates the precision error as an indicator for reproducibility. [14] The relationship between the patients' sex or the sides and the incidence of additional canals was determined using the chi-square test. Differences were considered significant when p < 0.05.…”
Section: Methodsmentioning
confidence: 99%
“…Values for the ICC ranged from 0 to 1. ICC values higher than 0.75 indicate good reliability, whereas a low CV demonstrates the precision error as an indicator of reproducibility (19). Pearson chi-squared test and ANOVA were performed (SPSS 17, Chicago, IL, USA) to assess the significance of inter-group differences in age, gender, and orthodontic malocclusion (P < 0.05).…”
Section: Methodsmentioning
confidence: 99%