A Comparison of the Haider Tube-Guard® Endotracheal Tube Holder Versus Adhesive Tape to Determine if This Novel Device Can Reduce Endotracheal Tube Movement and Prevent Unplanned Extubation

Abstract: BACKGROUND:Endotracheal tube security is a critical safety issue. We compared the mobility of an in situ endotracheal tube secured with adhesive tape to the one secured with a new commercially available purpose-designed endotracheal tube-holder device (Haider Tube-Guard®). We also observed for the incidence of oropharyngeal or facial trauma associated with the 2 tube fixation methods.METHODS:Thirty adult patients undergoing general anesthesia with neuromuscular blockade were prospectively enrolled. Immediately… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
22
1
4

Year Published

2017
2017
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(28 citation statements)
references
References 15 publications
1
22
1
4
Order By: Relevance
“…Buckley et al(2016) (23) supported the findings of the current study, they demonstrated how the use of Haider Tube-Guard compared to the adhesive tape and gauze role tap reduces the displacements of the endotracheal tube and decreasing the risk of UE. While the adhesive tape sticks to the surface of the patient face, the anchoragesof the tube of Haider Tube-Guard are fixed to the maxilla and jaw thus reducing the movements of the endotracheal tube.…”
Section: Discussionsupporting
confidence: 87%
“…Buckley et al(2016) (23) supported the findings of the current study, they demonstrated how the use of Haider Tube-Guard compared to the adhesive tape and gauze role tap reduces the displacements of the endotracheal tube and decreasing the risk of UE. While the adhesive tape sticks to the surface of the patient face, the anchoragesof the tube of Haider Tube-Guard are fixed to the maxilla and jaw thus reducing the movements of the endotracheal tube.…”
Section: Discussionsupporting
confidence: 87%
“…Reintubation is associated with complications including aspiration, fatal arrhythmia, cardiac arrest, and death [5,6]. Risk factors for unplanned extubation (even in the presence of physical restraints) also include disturbance in the fixation device, pain, sedation and weaning protocols, an impaired level of consciousness upon ICU admission, and the presence of nosocomial infection [7,8]. Unplanned extubation and reintubation are associated with increases in the likelihood of ventilator-associated pneumonia (13.8%e 27.6%), length of stay in the ICU (9e22 days), length of stay in the hospital (18e34 days), and number of days on mechanical ventilation (6 days) [9].…”
Section: Introductionmentioning
confidence: 99%
“…Researchers and experts have noted the importance of using the safest tools to fix the ET tube. [ 7 8 9 12 13 14 15 16 ] The Thomas tube holder was superior to adhesive tape in securing the ET tube in a mannequin to log roll, chest compressions, and transportation.…”
Section: Discussionmentioning