A comparison of the gamma index analysis in various commercial IMRT/VMAT QA systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

9
118
0
1

Year Published

2015
2015
2018
2018

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 137 publications
(130 citation statements)
references
References 40 publications
9
118
0
1
Order By: Relevance
“…On the other hand, one can question this method in general,27, 28 as there might be a lack of correlation between the results of the gamma‐analysis and the clinical implication 9, 11, 13, 14, 27, 29, 30, 31, 32. Furthermore, the optimal criteria might depend on the measurement device,11, 16, 17, 18 which is supported by our results.…”
Section: Discussionsupporting
confidence: 85%
See 1 more Smart Citation
“…On the other hand, one can question this method in general,27, 28 as there might be a lack of correlation between the results of the gamma‐analysis and the clinical implication 9, 11, 13, 14, 27, 29, 30, 31, 32. Furthermore, the optimal criteria might depend on the measurement device,11, 16, 17, 18 which is supported by our results.…”
Section: Discussionsupporting
confidence: 85%
“…In addition, improvements in tests for the correct beam model parameters were proposed 5, 6, 7, 8. Nevertheless, the evaluation of treatment plan QA is still cumbersome as shown by ongoing discussions about the widely used gamma‐evaluation method itself, the optimal evaluation parameters and the comparison between different measurement devices 9, 10, 11, 12, 13, 14, 15, 16, 17, 18…”
Section: Introductionmentioning
confidence: 99%
“…Such a problem is also present in IMRT plans, where the resolution of the detector can be inadequate in steep dose profiles, as the linear interpolation of measurements in a discrete array of detectors can produce an overly smoothed dose profile reconstruction. So the detector resolution together with the algorithm lead to a poor agreement when the dose profile is more modulated 15, 23, 24. On the contrary, in RapidArc delivery, the larger amount of acquired data produces a better estimation of measured dose.…”
Section: Discussionmentioning
confidence: 99%
“…The most popular methods of performing 2D gamma analysis use either 2D ion chamber or diode arrays. Hussein et al (7) investigated five commercial QA systems, including 2D ion chamber array PTW 2D‐array and 2D diode arrays ScandiDos Delta4 and Sun Nuclear ArcCHECK. The author concluded that good statistical agreement exists between predicted gamma based on virtual measurement relative to independent prediction.…”
Section: Introductionmentioning
confidence: 99%