2018
DOI: 10.14260/jemds/2018/1245
|View full text |Cite
|
Sign up to set email alerts
|

A Comparison of the Diagnostic Value of Magnetic Resonance Mammography Versus Ultrasound Mammography in Moderate- And High-Risk Breast Cancer Patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0
1

Year Published

2019
2019
2021
2021

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 27 publications
0
5
0
1
Order By: Relevance
“…In present study, the sensitivity of USG increased considerably owing to addition of multiple criteria and the fact that we used high-resolution USG and had a clinically suspected study population. Yahyazadeh and Mehraeen [26] , also reported both high sensitivity (91.7%) as well as high specificity (87.2%). Although, some workers like Stachs et al [21] , reported the sensitivity of conventional USG to be as high as 97.4% but reported the specificity to be too low (42.6%).…”
Section: Discussionmentioning
confidence: 87%
See 2 more Smart Citations
“…In present study, the sensitivity of USG increased considerably owing to addition of multiple criteria and the fact that we used high-resolution USG and had a clinically suspected study population. Yahyazadeh and Mehraeen [26] , also reported both high sensitivity (91.7%) as well as high specificity (87.2%). Although, some workers like Stachs et al [21] , reported the sensitivity of conventional USG to be as high as 97.4% but reported the specificity to be too low (42.6%).…”
Section: Discussionmentioning
confidence: 87%
“…A slightly lower sensitivity and specificity of MRI (88% and 80%) has been reported by ElSaid et al [20] in their study. Among different studies reviewed by us, a few studies reported specificity of MRI to be less than 80% -reporting them to be 69.7%, 50% and 57.5% respectively [23][24][25][26][27][28] but both the studies found it to be highly sensitive with sensitivity of 92.5%, 100% and 98.2% respectively.…”
Section: Discussionmentioning
confidence: 95%
See 1 more Smart Citation
“…Magnetic resonance (MR) image reconstruction technology has been long-established in clinical medical detection with the rapid development of medical image processing technology. It has become an essential means of medical diagnosis [1][2][3]. In practical medical applications, the traditional approach is to sample data according to the Shannon-Nyquist sampling technique.…”
Section: Introductionmentioning
confidence: 99%
“…A pesar de los importantes avances tecnológicos y médicos, la prevalencia del cáncer entre la población se mantiente en niveles alarmantes (3) es en torno a qué métodos de detección son mejores y, sobre todo en Europa y América, demanda hacia los gobiernos por medidas que protejan la salud, en especial para mujeres (4) . Sustancialmente se solicita programas de salud pública que garanticen los medios para el diagnóstico temprano del cáncer, gratuitos y de calidad (5) .…”
Section: Introductionunclassified