1970
DOI: 10.14219/jada.archive.1970.0255
|View full text |Cite
|
Sign up to set email alerts
|

A Comparison of Six Acrylic Resin Processing Technics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
5
0
1

Year Published

1977
1977
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 5 publications
1
5
0
1
Order By: Relevance
“…For both investment methods, statistically significant difference was observed in the denture base resin adaptation among regions, with a lower value for the canines region and a higher value seen for the posterior palatal. This interaction did not alter the pattern of adaptation verified in previous studies,6, 7, 10–13, 17, 26 whose results were similar to the obtained in this current investigation.…”
Section: Discussionsupporting
confidence: 92%
See 1 more Smart Citation
“…For both investment methods, statistically significant difference was observed in the denture base resin adaptation among regions, with a lower value for the canines region and a higher value seen for the posterior palatal. This interaction did not alter the pattern of adaptation verified in previous studies,6, 7, 10–13, 17, 26 whose results were similar to the obtained in this current investigation.…”
Section: Discussionsupporting
confidence: 92%
“…Denture base adaptation to the stone cast is not satisfactory, mainly in the midline regions of the central portion of the posterior border,4–9 and gap discrepancies in the adaptation are not easily corrected after complete denture processing 10. Denture base accuracy is also influenced by the types of PMMA polymers,5, 11, 12 depends upon the palate vault shape,13 stresses released,14–16 processing techniques of the dentures,17–24 and it is considered a critical and unresolved problem 25–31…”
Section: Introductionmentioning
confidence: 99%
“…After flasking and boiling the trial denture, the denture teeth selected were positioned on the flask. [15][16][17] The heat-activated polymerization acrylic denture base material (Lucitone 199 Denture Base Resin; Degudent) was packed and processed following the manufacturer's recommendations. After deflasking and polishing the overdenture, the maxillary overdenture was delivered (Fig 10).…”
Section: Techniquementioning
confidence: 99%
“…Repeat steps 8 and 9.After obtaining the patient's informed consent, the maxillary trial denture was used to process the maxillary overdenture using a compression‐molding technique with gypsum molds. After flasking and boiling the trial denture, the denture teeth selected were positioned on the flask 15–17 . The heat‐activated polymerization acrylic denture base material (Lucitone 199 Denture Base Resin; Degudent) was packed and processed following the manufacturer's recommendations.…”
Section: Techniquementioning
confidence: 99%
“…[ 1 2 3 4 5 6 ] Volumetric shrinkage of around 20%–21% was observed when methyl methacrylate monomer is directly polymerized to PMMA. [ 7 8 9 ] Volumetric shrinkage of 5%–9% is observed when the monomer is blended with the polymer. [ 8 10 11 12 ] The denture shrinkage along the posterior palatal region and lingual flanges antero-posteriorly compromises the retention and exerts pressure on the disto-buccal aspect of tuberosity, disto-lingual and antero-labial regions of the mandibular arch.…”
Section: Introductionmentioning
confidence: 99%