A Comparison of Black-blood T<sub>2</sub> Mapping Sequences for Carotid Vessel Wall Imaging at 3T: An Assessment of Accuracy and Repeatability

Abstract: Purpose: This study is to compare the accuracy of four different black-blood T 2 mapping sequences in carotid vessel wall. Methods: Four different black-blood T 2 mapping sequences were developed and tested through phantom experiments and 17 healthy volunteers. The four sequences were: 1) double inversion-recovery (DIR) prepared 2D multi-echo spin-echo (MESE); 2) DIR-prepared 2D multi-echo fast spin-echo (MEFSE); 3) improved motion-sensitized driven-equilibrium (iMSDE) prepared 3D FSE and 4) iMSDE prepared 3D … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 36 publications
0
5
0
Order By: Relevance
“… 111 , 112 Similar to the discrepancy among T1 measurement methods, T2 measurement methods are known to show disagreement with each other. 113 Jutras et al 114 reported that the WM T2 of 70 and 50 milliseconds was measured by MET2 and DESPOT2, respectively, in the same subject, partly due to the different weighting of each tissue component by these methods.…”
Section: Magnetic Resonance Imagingmentioning
confidence: 99%
“… 111 , 112 Similar to the discrepancy among T1 measurement methods, T2 measurement methods are known to show disagreement with each other. 113 Jutras et al 114 reported that the WM T2 of 70 and 50 milliseconds was measured by MET2 and DESPOT2, respectively, in the same subject, partly due to the different weighting of each tissue component by these methods.…”
Section: Magnetic Resonance Imagingmentioning
confidence: 99%
“…Furthermore, the scan time of the SQUMA imaging (scan time: 12 minutes) was shorter than that of 2D multi‐contrast vessel wall imaging (total scan time: 20 minutes) 34 and other combinations of quantitative T 1 , T 2 , and T 2 * mapping imaging (where the scan time depends on the acquisition approach). For example, the GOAL‐SNAP 18 technique for T 1 map estimation requires 5 minutes to acquire 0.8 mm isotropic resolution with a field of view of 100 × 100 × 100 mm 3 ; the iMSDE prepared T 2 map acquisition 19 requires 7 minutes 54 seconds to acquire 0.6 × 0.6 × 1.4 mm 3 resolution with a field of view of 140 × 140 × 42 mm 3 . SQUMA imaging ensures the quality and robustness of images without increasing the scan time.…”
Section: Discussionmentioning
confidence: 99%
“…18 The double inversion recovery (DIR) prepared 2D spin echo sequence and the improved motion-sensitized drivenequilibrium (iMSDE) prepared 3D spin echo or spoiled gradient echo (SPGR) sequence have been utilized for the acquisition of carotid T 2 maps. 19 The Dixon sequence and the MSDE prepared SPGR sequence have been used to acquire carotid T 2 * maps. 20 Investigators have also developed carotid MR quantitative imaging techniques which enable simultaneous acquisition of two MR quantitative parameters with a single sequence.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Finally, quantitative T2 (qT2) was performed with a multi-echo variable refocussing flip angle FSE sequence with improved Motion-Sensitized Driven-Equilibrium. The accuracy and repeatability of improved Motion-Sensitized Driven-Equilibrium prepared 3D variable refocussing flip angle fast spin echo for T2 mapping has previously been reported 16 . We used three echo times to generate qT2 maps after practical consideration of scanning time and accuracy.…”
Section: Mr Imagingmentioning
confidence: 92%