2001
DOI: 10.1016/s0021-9290(00)00219-0
|View full text |Cite
|
Sign up to set email alerts
|

A comparison of biomechanical properties between human and porcine cornea

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

4
181
0
11

Year Published

2004
2004
2021
2021

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 279 publications
(219 citation statements)
references
References 5 publications
4
181
0
11
Order By: Relevance
“…The research has concentrated on porcine corneas because of their close similarity with human corneas in structure and constitutive relationship (Zeng et al 2001). This work has enabled the identification of important aspects of the material properties and the determination of the significant factors that should be considered in the numerical modelling.…”
Section: Introductionmentioning
confidence: 99%
“…The research has concentrated on porcine corneas because of their close similarity with human corneas in structure and constitutive relationship (Zeng et al 2001). This work has enabled the identification of important aspects of the material properties and the determination of the significant factors that should be considered in the numerical modelling.…”
Section: Introductionmentioning
confidence: 99%
“…The uniaxial tensile tests are done using rectangular corneal strips subjected to tensile loading [1][2][3][4][5][6][7][8]. Because of the well-known limitations of this testing technique [9], it has often been used for comparative studies [3,6,10].…”
Section: Introductionmentioning
confidence: 99%
“…Because of the well-known limitations of this testing technique [9], it has often been used for comparative studies [3,6,10]. Compared to the uniaxial testing technique, inflation tests are able to better represent natural conditions of the cornea as they do not use excised samples [11,12].…”
Section: Introductionmentioning
confidence: 99%
“…Previous studies on cornea mechanics have typically employed a tensile strip method [64,3,35,45,89,86], or a more physiologically relevant inflation method [88,44,34,77]. These measurements have been used, for example, to study the efficacy of cross-linking agents as means to counteract keratoconous [86,80].…”
Section: Introductionmentioning
confidence: 99%
“…While previous work both at Sandia and in the literature [15,64,3,35,80,45,89,86], has primarily involved tensile tests of excised corneal strips, both the excision process and the uniaxial loading mode may produce results that are not physiologically meaningful. Specifically, the excision process severs off-axis collagen fibrils, and the subsequent tensile loading mode will only directly load the on-axis fibrils.…”
Section: Introductionmentioning
confidence: 99%