2019
DOI: 10.1097/ta.0000000000002545
|View full text |Cite
|
Sign up to set email alerts
|

A comparison between the TEG 6s and TEG 5000 analyzers to assess coagulation in trauma patients

Abstract: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require ap… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
64
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
2
2

Relationship

3
5

Authors

Journals

citations
Cited by 63 publications
(66 citation statements)
references
References 37 publications
2
64
0
Order By: Relevance
“…Comparisons to other whole-blood platelet function tests Multiplate® and VerifyNow® show TEG®6s is able to distinguish between healthy blood spiked with different concentrations of platelet inhibitor, with TEG®6s showing the best score for internal distribution of disagreement (5.0% for TEG®6s, 8.3% for VerifyNow® and 13.3% for Multiplate®) and lowest variability (5.1% for TEG®6s, 17.7% for VerifyNow® and 14.1% for Multiplate®) [20]. The TEG®6s is also smaller, more portable, and less sensitive to vibrations than previous models [9,21].…”
Section: Discussionmentioning
confidence: 98%
“…Comparisons to other whole-blood platelet function tests Multiplate® and VerifyNow® show TEG®6s is able to distinguish between healthy blood spiked with different concentrations of platelet inhibitor, with TEG®6s showing the best score for internal distribution of disagreement (5.0% for TEG®6s, 8.3% for VerifyNow® and 13.3% for Multiplate®) and lowest variability (5.1% for TEG®6s, 17.7% for VerifyNow® and 14.1% for Multiplate®) [20]. The TEG®6s is also smaller, more portable, and less sensitive to vibrations than previous models [9,21].…”
Section: Discussionmentioning
confidence: 98%
“…Although there is vigorous debate regarding the reproducibility of these VETs, for trauma patients who require massive transfusion with prohemostatic agents, these tests offer the same benefit in clinical outcomes as they have demonstrated for liver transplantations and the cardiac surgery patients. 119,120 With the evolution to a simplified tube or cartridge system and because of a new investigational cartridge system that can reliably predict DOAC activity, one can anticipate increased utilization of these tests at the site of care. Peripheral debates concerning the sensitivity of the VETs to guide the utilization of TXA in trauma do not detract from the welldesigned studies which show decreased mortality and blood utilization in those trauma patients whose resuscitation is guided by VETs.…”
Section: Resultsmentioning
confidence: 99%
“…The TEG ® 6s system has gained regulatory clearance in the USA and Europe amongst other international markets and has been compared to first-generation thromboelastography systems in the literature [19,[21][22][23]. The assays available with the TEG ® 6s are similar to the TEG ® 5000 and are available in three cartridge configurations.…”
Section: Teg ® 6s (Haemonetics)mentioning
confidence: 99%
“…Furthermore, unlike many of the first-generation devices that had significant inter-laboratory variance, with coefficients of variation >10% [18][19][20], these newer-generation devices have demonstrated reduced variance [21]. Whilst older-generation devices enabled users to focus on running channels of interest, newer devices detailed below require users to run entire cartridges.…”
mentioning
confidence: 99%
See 1 more Smart Citation