A comparison between ion-to-photon and microchannel plate detectors

Abstract: An alternative detector for time-of-flight mass spectrometry, the ion-to-photon detector, detecting light produced when ions impact a surface coated with a fluorescent compound, was compared to a conventional microchannel plate detector. Single ion experiments showed that, for a given energy, the efficiency of the ion-to-photon detector relative to the microchannel plate detector decreases as the molecular mass of the impinging ion increases. This decrease becomes less pronounced for larger ions. Seen as a fun… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

1999
1999
2016
2016

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 13 publications
0
5
0
Order By: Relevance
“…Because the number of ions leaving the mass analyzer at a particular instant is typically quite small, considerable amplification is often necessary to get a signal. Microchannel plate detectors are commonly used in modern commercial instruments (Dubois et al, 1999). In FT-MS and Orbitraps, the detector consists of a pair of metal surfaces within the mass analyzer/ion trap region which the ions only pass near as they oscillate.…”
Section: Detectorsmentioning
confidence: 99%
See 1 more Smart Citation
“…Because the number of ions leaving the mass analyzer at a particular instant is typically quite small, considerable amplification is often necessary to get a signal. Microchannel plate detectors are commonly used in modern commercial instruments (Dubois et al, 1999). In FT-MS and Orbitraps, the detector consists of a pair of metal surfaces within the mass analyzer/ion trap region which the ions only pass near as they oscillate.…”
Section: Detectorsmentioning
confidence: 99%
“…Conventional MS has relied on ionization-based detectors, namely those producing and multiplying secondary electrons associated with particle bombardment of a metal surface; such detectors are restricted to ions having a mass less than 10 6 Da. An ion-to-proton conversion detector (IPD) shows promise for detecting macro-ions (Dubois et al, 1997;Dubois et al, 1999). Photosensitive detectors, relying on laser-indued fluorescence (LIF) or elastic light scattering (ELS), show promise in this area.…”
Section: Post-acceleration Detectormentioning
confidence: 99%
“…The task of the TDC is to count the amplifi ed signal information it receives into time bins across a mass spectral scan. A typical mass spectral scan for a 4 GHz TDC consists of 20 time bins, which produce an approximately 50 µs scan window (Matsuura et al, 1985;Dubois et al, 1999). Each time the accelerator region pulses the ions, the TDC is initiated (Fig.…”
Section: The Time Of Fl Ight Refl Ectron Time Of Fl Ight and Quadrupmentioning
confidence: 99%
“…Other organic scintillators have also been investigated for applications in mass spectrometry. For example, Dubois, Zenobi, and co-workers 17,18 used the organic components But-PBD (2-(4-tert-Butylphenyl)-5-(4biphenylyl)-1,3,4-oxidiazole) and BBOT (2,5-bis(5 -tertbutyl-2-benzoxazolyl)thiophene) to build an ion-to-photon conversion detector (IPD). The detector consisted of a glass plate coated with a layer of the organic material and mounted in front of a PMT.…”
Section: Introductionmentioning
confidence: 99%