A comparison between 915 MHz and 2450 MHz microwave ablation systems for the treatment of small diameter lung metastases

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 22 publications
(14 citation statements)
references
References 29 publications
0
14
0
Order By: Relevance
“…These results may be explained by the ability of 2450 MHz MWA systems to deliver greater amounts of power and achieve larger ablation volumes 11. A recent observational study comparing 915 and 2450 MHz MWA for ablation of lung metastases found that ablation margin size was significantly associated with the local progression rate and that 2450 MHz MWA demonstrated a significantly better local progression-free survival curve than 915 MHz MWA (P=0.048) 59. Liu and colleagues did not report any differences in treatment effect when comparing these two MWA frequencies 60.…”
Section: Discussionmentioning
confidence: 99%
“…These results may be explained by the ability of 2450 MHz MWA systems to deliver greater amounts of power and achieve larger ablation volumes 11. A recent observational study comparing 915 and 2450 MHz MWA for ablation of lung metastases found that ablation margin size was significantly associated with the local progression rate and that 2450 MHz MWA demonstrated a significantly better local progression-free survival curve than 915 MHz MWA (P=0.048) 59. Liu and colleagues did not report any differences in treatment effect when comparing these two MWA frequencies 60.…”
Section: Discussionmentioning
confidence: 99%
“…Thermal ablation therapy has been widely used in many benign and malignant solid tumors such as uterine broids, liver cancer, pancreatic cancer, osteoid osteoma 22,23 . The technique is effective and safe, but there are still many scienti c and technical problems to be solved in the application of microwave thermal ablation in bone tumor surgery.…”
Section: Discussionmentioning
confidence: 99%
“…Although this allows ablation of larger targets, the shape of the coagulation zone becomes less predictable, which increases the risk of adverse effects as intravascular steam burns outside the target. MWA devices operating at 2450 MHz and above are applied to create an ablation zone that is smaller and more spherical than the zone with devices operating at 915 MHz [220,253,254]. Available devices at 2450 MHz include the cooled 14 gauge mini-choked HS AMICA (HS Hospital Service, Rome, Italy) [215,255], the Acculis (AngioDynamics, NY, USA) [216], the Solero (AngioDynamics, NY, USA), the Emprint Ablation System (Medtronic Inc, Minneapolis, MN, USA, formerly Covidien) [217,221] and the NeuWave Certus Microwave Ablation System (NeuWave Medical, Madison, Wisconsin) [256].…”
Section: Local Heating Techniquesmentioning
confidence: 99%